Furuno IC-307 Operator's Manual

Furuno IC-307 Operator's Manual

Ship security alert system (ssas) uscg version

Advertisement

OPERATOR'S MANUAL
SHIP SECURITY
ALERT SYSTEM (SSAS)
USCG Version
IC-307
Model
(For FELCOM 15/16/18/19)
www.furuno.com

Advertisement

Table of Contents
loading

Summary of Contents for Furuno IC-307

  • Page 1 OPERATOR'S MANUAL SHIP SECURITY ALERT SYSTEM (SSAS) USCG Version IC-307 Model (For FELCOM 15/16/18/19) www.furuno.com...
  • Page 2 9-52 Ashihara-cho, Nishinomiya, 662-8580, JAPAN A : AUG 2005 Printed in Japan All rights reserved. D : JAN . 23, 2015 Pub. No. OME-56352-D ( GREG ) IC-307(USCG Version) 0 0 0 1 5 7 1 6 0 1 3...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS SYSTEM CONFIGURATION ..................ii 1. OVERVIEW OF SSAS ..................1 2. INSTALLATION ....................3 2.1 Mounting ........................... 3 2.1.1 Junction box (for FELCOM 16/19) ................3 2.1.2 SSAS alert unit ......................4 2.2 Wiring ..........................6 2.2.1 Junction box (for FELCOM 16/19) ................6 2.2.2 SSAS alert unit ......................
  • Page 4: System Configuration

    Shipboard LAN (Ethernet) 12-24 VDC Printer 24 VDC PP-510 Mini Keyboard Distress Alert/ Received Call Unit IC-305 SSAS Alert Unit SSAS Alert Unit IC-307 IC-307 JUNCTION Alarm Unit (Max. 3 units) IC-306 IC-315 SSAS Alert Unit IC-307 : Standard Supply Navigator...
  • Page 5 PP-510. 5139U Navigator JUNCTION BOX IC-318 Distress Alert/ Received Call Unit IC-305/IC-350 SSAS Alert Unit SSAS Alert Unit SSAS Alert Unit Alarm Unit IC-307 IC-307 IC-307 IC-306 Max. 3 units FELCOM 19 ANTENNA UNIT IC-119 AC-DC Power Supply PR-240...
  • Page 6: Overview Of Ssas

    1. OVERVIEW OF SSAS The IC-307 SSAS (Ship Security Alert System) Alert Unit connects to the Inmarsat-C MES FELCOM 15/18 or the Inmarsat Mini-C FELCOM 16/19 for the purpose of alerting specified addresses (for example, your ship’s company) that your ship is under attack by intruders.
  • Page 7 SSAS operation flow Open the cover and press button one second. SSAS report is immediately transmitted. An LES sends acknowledgement to your ship. SSAS report is automatically sent to multiple addresses if applicable. Repeated transmission of the SSAS report begins. The interval at which to transmit the SSAS report to each address can be specifed.
  • Page 8: Installation

    2. INSTALLATION 2.1 Mounting 2.1.1 Junction box (for FELCOM 16/19) The junction box IC-315 is required when installing the SSAS on the FELCOM 16/19; it is already installed on the FELCOM 15/18. Separate the junction box from a magnetic compass by the distances shown below to prevent deviation to a magnetic compass.
  • Page 9: Ssas Alert Unit

    2.1.2 SSAS alert unit Separate the junction box from the SSAS alert unit by the distances shown below to prevent deviation to a magnetic compass. Standard compass: 0.70 m Steering compass: 0.45 m Locate the SSAS alert unit where it cannot be found by intruders. The location should be known only by ship’s captain and authorized personnel.
  • Page 10 5. Attach the switch cover as shown below. Note that the cover may also be rotated 180 degrees. Switch cover Flush mounting The optional flush mount kit OP16-28 (Code No. 004-448-010) is required. Name Type Code No. Remarks Fixture 16-018-7201-1 100-317-931 Pan head screw M3x6 000-800-362...
  • Page 11: Wiring

    For detailed wiring information see the interconnection diagram. For connecting the SSAS alert unit IC-307, use the JIS cable TTYCS-4 (or equivalent, see next page for sectional view of this cable) or the CO-SPEVV-SB-C 0.2x5P. When using the CO-SPEVV-SB-C 0.2x5P cable, replace the cable clamp with the cable clamp...
  • Page 12: Ssas Alert Unit

    No. 3 unit: Unit with one cable connnected to it. Two IC-307: No. 2 unit Two IC-307: No. 1 unit Three IC-307: No. 3 unit Three IC-307: No. 1 and No. 2 units 16P0229 16P0229 3 4 5 6 3 4 5 6...
  • Page 13: Enabling Uscg Version

    3. Type “furunoservice” (without quotation marks) in the Enter JOB No. field and then press the [Enter] key. The prompt PASSWORD appears. 4. Enter password (see FURUNO Information for SSAS) then press the [Enter] key. Then, the item Main Menu is displayed in reverse video.
  • Page 14: Operation

    3. OPERATION 3.1 Operation Mode There are two menu operating modes: Normal mode: Menus other than SSAS-related menus are displayed. SSAS manager mode: The mode is activated by the password entered by the ship’s captain or authorized personnel. The indication “SSAS Manager Mode”...
  • Page 15: Ssas Manager Mode

    3.1.2 SSAS manager mode All SSAS-related settings are set in the SSAS manager mode. Do the following to access this mode. 1. FELCOM 15: Press [F8], [2] to show the System Setup menu. FELCOM 16/18.19: Press [F8], [1] to show the System Setup menu. 2.
  • Page 16: Setting Ssas Report Destination And Message Contents

    3.2 Setting SSAS Report Destination and Message Contents When the SSAS is activated, the SSAS report is sent according to the addresses (max. 5 for FELCOM 15/16, 10 for FELCOM 18/19) and message content set with SSAS Report 1 – SSAS Report 5 for FELCOM15/16 or SSAS Report 10 for FELCOM 18/19 on the SSAS Report menu.
  • Page 17 4. Press the [↑] or [↓] key to choose the report number desired and then press the [Enter] key to display the window shown on the following page. SSAS Report SSAS Report Status Status Real+Test Real+Test Mode Mode Station Name Station Name TELEX TELEX/MES...
  • Page 18 15. Press the [2] key to display the SSAS Message Contents menu. SSAS Message Contents _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Vessel Name : _ _ _ _ _ _ _ _ _ MMSI...
  • Page 19 Load from FD Save to FD 1. ALL 1. ALL 2. Station List 2. Station List *: Availlable only in SSAS manager mode 3. LES List 3. LES List ("5.SSAS Report" is added in the SSAS 4. E-Mail Service List 4.
  • Page 20: Transmitting Ssas Report

    3.3 Transmitting SSAS Report The SSAS report is sent one second after the button on the SSAS is pressed. Repeated transmission can only be stopped from the SSAS manager mode. 1. Open the cover of the SSAS alert button. Cover 2.
  • Page 21: Testing The Button

    Note: If you accidentally push the button in, push it again within 30 seconds to cancel the report. The button pops out ( ) and the report is not transmitted. When this is done, the message “INF: SSAS UNIT activation has been canceled.” appears on the display. Additionally, for the FELCOM 16/19, the POWER lamp on the communication unit flashes 30 seconds.
  • Page 22 Options Test 1. Login Distress/SSAS Button Test 2. Logout 1. PV Test 3. Abort 2. PV Test Result 4. Select NCS 3. Self Test Distress/SSAS buttons are under test mode. CAUTION 5. Ocean Region 4. Distress Alarm Button Test Press any key to escape. INF: SSAS Buttons entered into TEST MODE.
  • Page 23 FELCOM 16/19, no PC Turn off communication unit. Turn on button of No. 1 SSAS. Turn on communication unit. 30 s POWER, LOGIN and TX lamps flash in that order. Send SSAS No (within 30 s) test report? Yes (after 30 s) SSAS report is sent to station(s) whose mode is "Real+Test"...
  • Page 24 FELCOM 16/19, PC version 1. Press the [F7] key to display the Options menu. 2. Press the [7] key ([6] key when the FELCOM functions as an EGC receiver) to display the Test menu. For FELCOM 19, press the [8] key. Test 1.
  • Page 25: Ssas Report Test

    3.5 SSAS Report Test You can test for successful transmission of the SSAS report to the address you specify, without using the button. The test report message states “!!! Test Call !!!” to alert the receiver of the message that it is a test call. Note: This function is only available in the SSAS manager mode.
  • Page 26: Waterproofing Kit

    4. WATERPROOFING KIT To mount the IC-305 and IC-307 on a bulkhead, use the optional waterproofing kit to keep water splash out of the units. Note: This kit cannot be used if the IC-305 or IC-307 is mounted face upward.
  • Page 27 Mar.03'05...
  • Page 28 Y.NISHIYAMA 17/May/2012...
  • Page 29 Y. NISHIYAMA 6/Oct/2010...
  • Page 31: Interconnection Diagrams

    *5. TB BOARD (16P0116) REQUIRED. SCALE MASS NAME INMARSAT-C MES CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5 *6. CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE. CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5 DWG No. INTERCONNECTION DIAGRAM *7. DO NOT SHORTEN ANTENNA CABLE. C5635-C01- T FURUNO ELECTRIC CO., LTD.
  • Page 33 *1: SHIPYARD SUPPLY. 相互結線図 Y.NISHIYAMA 18/Dec/2012 *2: OPTION. SCALE MASS NAME INMARSAT-C MES *3: CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE. CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5 *4: STANDARD CONFIGURATION FOR SSAS. CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5 DWG No. REF.No. INTERCONNECTION DIAGRAM C5674-C01- D 16-023-3001-1...

This manual is also suitable for:

Felcom 15Felcom 16Felcom 18Felcom 19

Table of Contents