Button
3.6.5

Resetting FastApp

>
Fig. 3-13: Submenu – Resetting FastApps
Button
Apex Tool Group
Description
 Enter the minimum angle.
 Enter the final speed.
 Enter speed threshold.
As soon as the spped threshold is reached, the speed immediately changes from the
start speed to the final speed up to the maximum torque.
>
>
1
Description
 Press to cancel the process.
→ The settings for the selected FastApp are not reset.
→ Reset FastApp is exited.
 Press to reset the FastApps menu.
→ All settings for the selected FastApp are deleted.
→ The Reset FastApp menu is exited.
→ Since the FastApp is no longer parameterized, the symbol
the Configure FastApps menu and this FastApp
the run screen.
P2398PM | 2019-12
Menus and Functions
is displayed in
can no longer
be selected on
3
EN
23