Maintenance; General Notes On Maintenance; Cleaning The P-73X - PI P­73 Series User Manual

Nanopositioner
Hide thumbs Also See for P­73 Series:
Table of Contents

Advertisement

7 Maintenance

7
Maintenance
In this Chapter

General Notes on Maintenance ................................................................................................... 31

Cleaning the P-73x ....................................................................................................................... 31

7.1
General Notes on Maintenance
NOTICE
Misalignment from loosening screws!
The P-73x is maintenance-free and achieves its positioning accuracy as a result of the optimal
alignment of mechanical components and piezo actuators. Loosened screws cause a loss in
positioning accuracy.
 Loosen any screws only when instructed in this manual.
 Do not open the P-73x.
7.2
Cleaning the P­73x
NOTICE
Damage from ultrasonic cleaning!
Ultrasonic cleaning can damage the P-73x.
 Do not do any ultrasonic cleaning.
Requirements
 You have discharged the piezo actuators of the P-73x (p. 29).
 You have disconnected the P-73x from the electronics.
Cleaning the P­73x
 Clean the surfaces of the P-73x with a cloth dampened with a mild cleanser or
disinfectant (e.g., isopropyl alcohol).
P­73x Nanopositioner
PZ103E
Version: 1.1.0
31