NOTICE
Misalignment from loosening screws!
The P-73x is maintenance-free and achieves its positioning accuracy as a result of the optimal
alignment of mechanical components and piezo actuators. Loosened screws cause a loss in
positioning accuracy.
Loosen any screws only when instructed in this manual.
Do not open the P-73x.
7.2
Cleaning the P73x
NOTICE
Damage from ultrasonic cleaning!
Ultrasonic cleaning can damage the P-73x.
Do not do any ultrasonic cleaning.
Requirements
You have discharged the piezo actuators of the P-73x (p. 29).
You have disconnected the P-73x from the electronics.
Cleaning the P73x
Clean the surfaces of the P-73x with a cloth dampened with a mild cleanser or
disinfectant (e.g., isopropyl alcohol).