Standby Power - medemagroup Mini Crosser X2 4W Service Manual

Hide thumbs Also See for Mini Crosser X2 4W:
Table of Contents

Advertisement

Medema A/S
Service manual 1533-2002-S
Note!
The Mini Crosser X2 uses a little power, even when the key
is turned to 0. We therefore recommend that the Mini Crosser
always be connected to the charger when not in use.

Standby power

The X2 Mini Crosser is equipped with an advanced display so-
lution. The system requires that there is always a small standby
power consumption of 70 mA.
If you do not make sure that the Mini Crosser is set to charge at
appropriate intervals, the batteries will fully discharge over time.
For this reason, we recommend that the Mini Crosser is always
set to charge when it is not being used.
Below is a recommended schedule of how many days before
a brand new battery is 100% discharged. The discharge time
depends on factors such as the ambient temperature, age and
how many Ah the battery has been rated in C20.
Ah in C20
85 Ah
110 Ah
The calculations in the table is only guiding!
Note
If the battery is 100% discharged, it is not possible for the
charger to start charging the battery.
There is no warranty on batteries that have been damaged as a
result of deep discharging.
If you are not using the Mini Crosser for a longer period of time,
for example during winter storage, you can choose to discon-
nect the one pole to the fully charged batteries. This way there
will be no consumption of standby power.
100% discharged after
47 days
65 days
39 of 122