Appendix A - Electric Faults - medemagroup Mini Crosser X2 4W Service Manual

Hide thumbs Also See for Mini Crosser X2 4W:
Table of Contents

Advertisement

Medema A/S

Appendix A - Electric faults

Code Description
0003
EEProm cache checksum
0100
ROM checksum trip
0200
EEProm cache checksum
0300
Parallel speed pot wiper open-
circuit
0704
Internal 12v supply Fault
0815
Throttle reference fault
0816
Throttle reference fault
0A00
Sleep timer
0A01
Keyswitch has been turned off
0E07
Throttle ISO Test Fault
Throttle ISO Test Fault
0E08
Throttle wiper fault
Throttle wiper fault
1310
Overcurrent fault
1500
Solenoid Brake Fault
1502
Solenoid Brake Fault
Solenoid Brake Fault
1504
Solenoid Brake Fault
1600
Battery voltage too high
Battery voltage too high
1601
Battery overvoltage Trip
1703
Relay interlock fault
1705
Possible Relay Fault
Possible Relay Fault
Service manual 1533-2002-S
Action Mode
Bars Comments
Trip
All modes 8
Trip
All modes 8
Trip
Startup
8
Limp
All modes 7
Trip
All modes 8
Trip
All modes 7
Trip
Startup
7
Trip
Standby
6
Trip
All modes 6
Trip
Startup
7
Trip
All modes 7
Trip
Startup
7
Trip
All modes 7
Trip
Drive
8
Trip
Drive
9
Trip
Startup
9
Trip
Standby
9
Trip
Startup
8
Trip
Startup
10
Trip
All modes 10
Trip
All mo-
10
dels
Trip
Startup
8
Trip
Startup
8
Trip
Standby
118 of 122
Internal Fault. Return to PGDT if
happening all the time.
Internal Fault. Return to PGDT if
happening all the time.
Internal Fault. Return to PGDT if
happening all the time.
Only tested if speed pot enabled.
Internal Fault. Return to PGDT if
happening all the time.
Value checked for valid range. Tests
only if "reference tests" enabled
Startup
If active (greater than 0) then it will
pulse trucharge gauge, recycle
keyswitch to reset.
Informs of rapid power cycle on key-
switch input, controller may not reset
correctly
Test only if ISO tests enabled, 10K
resistor, in series with wiper
Test only if ISO tests enabled, 10K
resistor, in series with wiper
Trips if throttle wiper exceeds limits
Trips if throttle wiper exceeds limits
Internal Fault. Return to PGDT if
happening all the time.
Trips if solenoid brake is short-circui-
ted, if test is enabled.
Trips if solenoid brake is short-circui-
ted, if test is enabled
Trips if solenoid brake is short-circui-
ted, if test is enabled
Internal Fault. Return to PGDT if
happening all the time.
Battery voltage is greater than 35.0V
Battery voltage has risen above
35.0V, possibly under regen.
Battery voltage has risen above
35.0V, possibly under regen.
Internal Fault. Return to PGDT if
happening all the time.
Internal Fault. Return to PGDT if
happening all the time.
As above, but can also be caused
by intermittent loss of battery voltage
during use.
Version 1.0.5 - 2021

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mini crosser x1 4wMini crosser child x1 3wMini crosser child x2 3wMini crosser x2 3wMini crosser x1 3w

Table of Contents