Panel Ms 200 And Ms 300 Setup Parameters - Kemppi FastMig MS 200 Operating Manual

Hide thumbs Also See for FastMig MS 200:
Table of Contents

Advertisement

2.6

Panel MS 200 and MS 300 setup parameters

Normal MIG welding Setup -parameters
Name of parameter
Pre Gas Time
Post Gas Time
Creep Start
Creep Start Level
Start Power
Post Current Time
Arc Voltage
Cable Length
EN
Synergic MIG -welding SETUP -parameters
Name of parameter
Pre Gas Time
Post Gas Time
Creep Start
Creep Start Level
Hot Start Level
Hot Start 2T Time
Crater Fill End Level
Crater Fill Start Level
Crater Fill Time
Wise Fusion On
Wise Fusion Percent
Wise Penetration On
Penetration Level
MiniLog On
14
FastMig MS 200, MS 300
Name on
Parameter
display
values
PrG
0.0 – 9.9 s
PoG
0.0 – 9.9 s
Cr
OFF, on
CrE
10 – 170%
StA
-9 ... +9
PoC
-9 ... +9
Ard
OFF, on
CAb
std, 5 – 80m
Name on
Parameter
display
values
PrG
0.0 – 9.9 s
PoG
0.0 – 9.9 s
Cr
OFF, on
CrE
10 – 170%
Hot
-50 ... 75%
H2t
0.0 – 9.9 s
CrL
10 – 250%
CrS
10 – 250%
CrT
0.0 – 9.9 s
FUS
OFF, on
FUP
10...60%
PE
OFF, on
PEn
-30 ... +30%
ML
on, OFF
Factory
Description
setting
0,0 s
Pre gas time in seconds
Aut
Post gas time in seconds or automatically
according to welding current (Aut)
OFF
Switch creep start on or off.
50%
Percentage of wire feed speed:
10% slowed start
100% = no creep start function
170% accelerated start
0
Strength of start pulse
0
Post current
OFF
on: Display shows arc voltage
OFF: Display shows pole voltage
std
Cable loss is calculated for optimal arc
control and for the Arc Voltage display
Factory
Description
setting
Syn
Pre gas time in seconds or automatically
according to synergic welding program
(Syn)
Syn
Post gas time in seconds or automatically
according to synergic welding program
(Syn)
OFF
Switch creep start on or off.
50%
Percentage of wire feed speed:
10% slowed start
100% = no creep start function
170% accelerated start
30%
Percentage of welding power:
-50% cold and +75% hot
1.2 s
The duration of the hot start in seconds in
2T mode
30%
The welding power at the end of the crater
fill stage as a percentage of the welding
power preset value
30%
The welding power at the beginning of
the crater fill stage as a percentage of the
welding power preset value
2.0 s
The duration of the crater fill stage in
seconds (only in 2T mode)
OFF
Switch Wise Fusion on/off (only in 1-MIG)
25%
Percentage of Wise Fusion (only in 1-MIG)
OFF
Switch Wise Penetration on/off (only in
1-MIG)
0%
Set the arc length where penetration
control begins (only in 1-MIG)
OFF
Switch on/off MiniLog

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fastmig ms 300Mxf 63Mxf 65Mxf 6761363006136400

Table of Contents