3.4.5. Setup parameters

To enter the setup you have to press back and forward arrows for three seconds:
Press 3 seconds for entering setup
Parameter
Explanation
A.
1
TIG slopes to minimum current
0*
TIG current at arc stop is 15 % of welding current
b.
1
no load voltage 30 V (VRD function)
0*
no load voltage 95 V
C.
1
by 2T the downslope is cut off by short (<0,4 s) action of the torch switch
0*
current can be sloped down and up again
d.
3
Minilog + SearcArc
2
4T-LOG + Minilog
1*
Minilog
0
4T-LOG
E.
Current Level at ignition (with upslope)
5-40%
Range
20 % *
Factory default
F.
1
Factory settings recall
0*
Factory default
h.
Pregas time minimum
0.0- 2.0 s
Range
0.0 s*
Factory default
J.
Postgas time minimum
0-10 s
Range
1 s*
Factory default
L.
Pregas time maximum
5-20 s
Range
10 s*
Factory default
o.
Postgas time maximum
15-99 s
Range
30 s*
Factory default
S.
MMA Dynamics adjustment
-3...5
Range
0*
Factory default
* (asterix) presents the factory default setting