9. SETUP PANEL CARD P001
9.1. Setup panel card P001
Purpose is to set and adjust machine operation parameters
•
9.2. Connectors
10. OTHER COMPONENTS
10.1. Secondary choke L002
The secondary choke reduces the ripple contents of secondary current
•
To achieve better welding properties L002 is constructed so that choke saturates in certain voltage and current values
•
10.2. Shunt resistor R002
Secondary current is measured with the shunt resistor
•
10.3. Output RFI filter unit RC001
Capacitors C001 to C005, varistor R003 and two power resistors forms a radio frequency interference (RFI) unit to re-
•
duce radio frequency interference.
10.4. Machine output terminals X002, X003 and X004
Machine has two (+) terminals X002 and X003 and one (-) terminal X004
•
10.5. Auxiliary transformer T002
The auxiliary transformer (T002) is a toroid transformer. It has 400 V primary and 38V and 20V secondary.
•
20V secondary supplies the control card A001 circuitry and the fans M001 and M002
•
38V secondary voltage is rectified with auxiliary rectifier (G003) to 50V dc –voltage
•
10.6. Auxiliary rectifier bridge G003
50V dc voltage supplies the serial communication bus and devices that are connected to it
•
Kemppi OY
SERVICE MANUAL
FASTMIG X
Connector
Description
X1:1
-
X1:2
-
X1:3
-
X1:4
-
X1:5
-
X1:6
-
X1:7
-
X1:8
-
X1:9
X1:10
X1:11
can data
X1:12
can rxd
X1:13
can txd
X1:14
+ 15 V
X1:15
+ 5 V
X1:16
gnd