MiniLog Level
Synergic Start Time
Synergic Start
Voltage
Start Power
Post Current Time
Synergic MIG Unit
Arc Voltage
Cable Length
© Kemppi Oy / R03
MLo
-99 ... +200%
FSt
-9 ... +9
FuL
-30 ... +30
StA
-9 ... +9
PoC
-9 ... +9
Unl
m/min, mm, A
Ard
OFF, on
CAb
std, 5 – 80m
50%
Set the minilog power level as a
percentage of the welding power
0
Star time in WiseRoot/WiseThin welding
0
Voltage level in the beginning of
WiseRoot/WiseThin welding
0
Strength of start pulse
(not in WiseRoot or WiseThin)
0
Post current
m/min
In 1-MIG and WiseRoot welding, the
parameter shown in left-hand display:
wire feed speed (m/min), sheet thickness
(mm) or average current (A)
OFF
on: Display shows arc voltage
OFF: Display shows pole voltage
(not in WiseRoot or WiseThin)
std
Cable loss is calculated for optimal arc
control and for the Arc Voltage display
(not in WiseRoot or WiseThin)
EN