Panel Sf 51 And Sf 54 Setup Parameters - Kemppi FastMig SF 51 Operating Manual

Hide thumbs Also See for FastMig SF 51:
Table of Contents

Advertisement

Remote Selection Button (13)
Remote control unit is connected to the device by pressing button 13. The wire feed speed
and welding voltage setting operations are performed via remote control. In this case,
potentiometers 11 and 12 of the panel are disconnected.
2.4

Panel SF 51 and SF 54 Setup parameters

Normal MIG welding Setup -parametres
Name of
parameter
Pre Gas Time
Post Gas Time
EN
Creep Start Level
Start Power
Post Current Time
Arc Voltage
Cable Length
Common Setup -parameters for MIG processes
Name of
parameter
Device Address
Using features of
PMT Gun
Gas Guard
Connected
LongSystem Mode
Code Entry
Water Cooler
Wire Inch Stop
8
FastMig SF 51, SF 54
Name on
Parameter
Factory
display
values
setting
PrG
0.0 – 9.9 s
0,0 s
PoG
0.0 – 9.9 s
Aut
CrE
10 – 170%
50 %
StA
-9 ... +9
0
PoC
-9 ... +9
0
Ard
OFF, on
OFF
CAb
std, 5 – 80m std
Name on
Parameter
Factory
display
values
setting
Add
3 or 6
3
Gun
OFF, on
on
GG
no, YES
on
LSY
OFF, on
OFF
Cod
---, Ent
---
Coo
OFF, on
on
Inc
OFF, on
on
Description
Pre gas time in seconds
Post gas time in seconds or automatically according to
welding current (Aut)
Percentage of wire feed speed:
10 % slowed start
100 % = no creep start function
170 % accelerated start
Strength of start pulse
Post current
on: Display shows arc voltage
OFF: Display shows pole voltage
Cable loss is calculated for optimal arc control and for the
Arc Voltage display
Description
Wire feeder bus address
on = PMT gun
OFF = other gun
Implementation of gas guard
on: Gives optimum welding characteristics with long
welding cables
Entering license codes manually:
1. Adjust right potentiometer to ('Ent').
2. Press REMOTE.
3. Set code with right potentiometer.
4. Choose next with left potentiometer.
5. Go back to point 3, until all codes have been set.
6. Approve by pressing REMOTE. ('Suc cEs')
Enables water cooler
OFF = Stops wire inch in case arc does not ignite
on = Feeds wire as long as the welding gun start switch
is pressed.