Weld data (11)
The weld data function is activated by long-pressing the additional welding functions button.
The weld data function returns the welding current and voltage values to the displays that
were in use during the last weld.
Selection of welding process (10)
The welding process – normal MIG or 1-MIG – can be chosen with the welding process
selection button. In normal MIG welding wire feed speed and welding voltage is adjusted
separately. In synergic 1-MIG and Wise welding the welding voltage and other parametres
related to welding are optimally bound to each other! In synergic welding the setting for
power and arc lenght are adjusted.
Electrode welding (MMA) is selected by pressing the button for >1 second. When electrode
welding is selected, the power source, the electrode holder connected to it and the MIG gun
become energised (open circuit voltage).
LED indicators: MMA (MMA selected), MIG (MIG selected), 1-MIG (1-MIG selected), 1-MIG +
WISE (1-MIG and either WiseFusion or WisePenetration selected , selection between the two is
done through SETUP) and WISE (WiseRoot or WiseThin selected, selection between the two is
done through welding program selection).
WiseRoot/WiseThin program is activated by choosing a WiseRoot/WiseThin welding program
(WISE led then turns on). Wise welding is the facility provided separately, so the function is
not in every equipment. WiseRoot and WiseThin require licences, which can be purchased in
Kemppi DataStore.
Selection of MIG operating procedure (5)
MIG 2T: MIG welding with two-sequence procedure of welding gun start switch
1.
switch pressed: welding starts
2.
switch released: welding stops
MIG 4T: MIG welding with four-sequence procedure of welding gun start switch
1.
switch pressed: shielding gas flow starts
2.
switch released: welding starts
3.
switch pressed: welding stops
4.
switch released: shielding gas flow stops
Minilog: Minilog is an additional function, which can be purchased separately. (Minilog is also
referred as 'Matchlog' in DataStore.)
Without Minilog license, press of the button chooses between 2T and 4T.