64

Weekly

1. Isolate the electrical power and compressed air supplies to the system.
2. Check the security of all fixtures and fittings, ensuring that all guards are securely
fastened in place.
3. Check that all electrical interlocks and emergency stops listed below function
correctly:
Emergency Stop buttons on the front panel and rear door.
Front panel, lid, rear door, infeed cover and outfeed cover interlocks.
Red lamp failure.
4. Check that the system and associated equipment has been cleaned correctly and
there is no build-up of product or debris.
5. Check that the lead impregnated curtains are in good condition and not damaged
in any way.
6. Inspect the conveyor belt for damage, contamination and deterioration.
7. Check that the conveyor belts are correctly tensioned and are neither too tight nor
too slack. If a belt feels too loose but is still capable of moving the product without
slippage, it may need to be adjusted.
Over tensioning a belt may cause damage to bearings and motors
8. Check that the external fan blades are clear of dust and debris.
For more detailed information on Maintenance see the relevant X
Document Number: 814212-2.0-ENG
Inspection and Cleaning
Reference Guide.