Loma X5c Operating Instructions Manual page 61

X-ray inspection system
Table of Contents

Advertisement

Operating Instructions
A numeric keypad is displayed.
2. Enter the new Pack Threshold value between a minimum of 80 and a
maximum of 254.
For example, if the screen is constantly capturing a white image then the
threshold may be set too high or the conveyor belt may need to be
cleaned.
Alternatively if the system is not grabbing images of the pack then the
threshold may be set too low or the product / system may need to be re-
calibrated.
3. Tap OK.
4. The Pack Threshold is updated
Measure
used to roughly measure the pack length. You should increase the length entered in
the Pack Length field by around 10% to allow for pack skew/presentation problems.
Learn Product:-Tapping on this displays a dialog to confirm that you wish to
initiate a new product learn process, overwriting the existing product parameters.
Tapping Yes displays the Learn Product Settings screen. For more information see
Learn Product.
Original Document
- This displays the Measure screen which contains a ruler that may be
Copyright © 2017 Loma Systems
57

Hide quick links:

Advertisement

Table of Contents
loading