Setting Lcp Display Values; Display Menu Keys - Danfoss VLT FC 103 Instruction Manual

Refrigeration drive
Hide thumbs Also See for VLT FC 103:
Table of Contents

Advertisement

User Interface

4.1.2 Setting LCP Display Values

The display area is activated when the adjustable
frequency drive receives power from AC line voltage, a DC
bus terminal, or an external 24 V DC supply.
The information displayed on the LCP can be customized
for user application.
Each display readout has a parameter associated
with it
Options are selected in the quick menu Q3-13
Display Settings
Display 2 has an alternate larger display option
The adjustable frequency drive status at the
bottom line of the display is generated automat-
ically and is not selectable
Status
0.0%
1.1
1.2
Off Remote Stop
2
3
Figure 4.2 Display Readouts
Display
Parameter number
1.1
0-20
1.2
0-21
1.3
0-22
2
0-23
3
0-24
Table 4.1 Legend to Figure 4.2
MG16E222
Instruction Manual
1 (1)
0.00 A
0.00 kw
0.0Hz
2605kWh
1.3
Default setting
Reference %
Motor current
Power [kW]
Frequency
kWh counter
Danfoss A/S © Rev. 2014-02-10 All rights reserved.

4.1.3 Display Menu Keys

Menu keys are used for menu access for parameter set-up,
toggling through status display modes during normal
operation, and viewing fault log data.
Quick
Status
Menu
Figure 4.3 Menu Keys
Key
Function
Status
Shows operational information.
In Auto mode, press to toggle between
status readout displays.
Press repeatedly to scroll through each
status display.
Press [Status] plus [
display brightness.
The symbol in the upper right corner of the
display shows the direction of motor
rotation and which set-up is active. This is
not programmable.
Quick Menu
Allows access to programming parameters for
initial set-up instructions and many detailed
application instructions.
Press to access Q2 Quick Set-up for
sequenced instructions to program the basic
adjustable frequency drive set-up
Follow the sequence of parameters as
presented for the function set-up.
Main Menu
Allows access to all programming parameters.
Press twice to access top-level index.
Press once to return to the last location
accessed.
Press to enter a parameter number for
direct access to that parameter.
Alarm Log
Displays a list of current warnings, the last ten
alarms, and the maintenance log.
For details about the adjustable frequency
drive before it entered the alarm mode,
select the alarm number using the
navigation keys and press [OK].
Table 4.2 Function Description Menu Keys
Main
Alarm
Menu
Log
] or [
] to adjust the
43
4
4

Advertisement

Table of Contents
loading

Table of Contents