Danfoss VLT FC 103 Instruction Manual page 84

Refrigeration drive
Hide thumbs Also See for VLT FC 103:
Table of Contents

Advertisement

Specifications
Adjustable frequency drive
Typical Shaft Output [kW]
Typical Shaft Output [HP] at 460 V
IP20/Chassis
IP21/NEMA 1
IP55/Type 12
IP66/NEMA 4X
Output current
Continuous (3x380–439 V) [A]
Intermittent (3x380–439 V) [A]
Continuous (3x440–480 V) [A]
Intermittent (3x440–480 V) [A]
Continuous kVA (400 V AC) [kVA]
Continuous kVA 460 V AC) [kVA]
Max. input current
Continuous (3x380–439 V) [A]
Intermittent (3x380–439 V) [A]
Continuous (3x440–480 V) [A]
Intermittent (3x440–480 V) [A]
Additional specifications
Estimated power loss at rated max. load [W]
IP20 max. cable cross-section (line power, brake,
motor and load sharing)
IP21, IP55, IP66 max. cable cross-section (line power,
motor) [mm
IP21, IP55, IP66 max. cable cross-section (brake, load
sharing) [mm
10
10
With line power disconnect switch included:
Weight enclosure IP20 (lb [kg])
Weight enclosure IP21 (lb [kg])
Weight enclosure IP55 (lb [kg])
Weight enclosure IP66 (lb [kg])
3)
Efficiency
Table 10.5 Line Power Supply 3x380–480 V AC – Normal overload 110% for 1 minute
80
7)
2
/(AWG)]
2
/(AWG)]
Danfoss A/S © Rev. 2014-02-10 All rights reserved.
Instruction Manual
P37K
37
50
B4
C1
C1
C1
73
80.3
65
71.5
50.6
51.8
66
72.6
59
64.9
4)
739
50 (1)
35/2
51.81 [23.5]
77.16 [35]
99.21 [45]
99.21 [45]
99.21 [45]
99.21 [45]
99.21 [45]
99.21 [45]
0.98
P45K
P55K
45
55
60
75
C3
C3
C1
C1
C1
C1
C1
C1
90
106
99
117
80
105
88
116
62.4
73.4
63.7
83.7
82
96
90.2
106
73
95
80.3
105
843
1083
150 (300 MCM)
150 (300 MCM)
95 (3/0)
35/2
70/3/0
77.16 [35]
110.23 [50]
99.21 [45]
143.3 [65]
99.21 [45]
143.3 [65]
99.21 [45]
143.3 [65]
0.98
0.98
P75K
P90K
75
90
100
125
C4
C4
C2
C2
C2
C2
C2
C2
147
177
162
195
130
160
143
176
102
123
104
128
133
161
146
177
118
145
130
160
1384
1474
185/kcmil350
110.23 [50]
143.3 [65]
143.3 [65]
143.3 [65]
0.98
0.99
MG16E222

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT FC 103 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents