TABLE 1. APPLIANCE DETAILS
Model
Features
Data Plate
Input
Output (High)
Efficiency
Heating area
Note: * will vary accordingly to gas type and flue configuration. ** will vary depending to geographical location.
Installation Types
Combustion Method
Flue - Masonry
Flueing - False Chimney
Convection Fan
Gas Connection
Gas Type
Electrical
Ignition
Power Consumption
Safety Devices
Glass - Primary Glass - Secondary
Glass seal material
Lighting
Weight (Engine Only)
Operation
Noise Level
Refer to appliance data plate for Gas Type, Gas Rates, Injector Sizes and Burner Pressures.
NOTE
Rinnai
Rinnai 650 (RDV600ER)
Inbuilt Gas Space Heater
Burning Log effect or Stone Fire Bed Effect Glass front
Convection Fan, top warm air outlet Glass dress guard
Infra Red (IR) remote control
Located on the lower RHS of the base panel in front of the gas control.
12~23 MJ/h
5.2* kW
79.4% (on high)
up to 78 m² **
Masonry Fireplace, False Fireplace and Inbuilt (weather proof box).
Bunsen type burner
Co-linear flexi flue, air intake Ø75mm, exhaust Ø100mm. Appliance MUST
BE installed with a Rinnai flue System.
Co-linear (air intake Ø75mm, exhaust Ø100mm) to Coaxial direct vent
flueing (inner Ø100mm, outer Ø170mm).
Appliance must be installed with a Rinnai flue System.
120V AC 50 Hz-2-speed centrifugal blower
Brass 1/2" BSPT male fitting, the gas supply terminates inside the heater -
lower right hand side of the appliance.
NG, Propane, Universal LPG (Universal LPG, New Zealand Only).
This heater has a 1.5 m power cord with a three pin plug supplied, the
power cord passes through a slot in the back right hand corner of the
appliance.
230-240 V AC 50 Hz high voltage electronic spark ignition
When on High, 115W
When on Standby, less than 1W
Overheat Switch
Pressure relief on glass panel - burner box Thermal Fuse, over-current
fuse
Flame Failure Sensing System
Refer to "SAFETY DEVICES" on page 7 of the Operation Manual for
information regarding additional safety devices and features.
Ceramic Glass Tempered Glass Woven fibreglass chord
Halogen Lamps 230 V 25W x 2.
51 Kg - "un-crated" - no Flue.
Push button control panel, Infra Red Remote Control.
37~45 dB(A)
33

SPECIFICATIONS

Rinnai 750 (RDV700ER)
14~27 MJ/h
6.1* kW
77.4% (on high)
up to 91 m² **
55 Kg - "un-crated" - no Flue.
RDV 600_700ER IM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rdv700er