Application
Certification
General Description
Operation
Gas Connection
Gas Control
Burners
Temperature Control
Logs
Ignition System
Flue System
Electrical Connection
Fan
Weight
AFUE
Venting
Minimum supply gas pressure
Maximum supply gas pressure
Manifold test pressure
BTU/hour input
BTU/hour output
Rinnai is continually updating and improving products. Therefore, specifications are subject to change without
prior notice.
4

Specifications

Vented gas fireplace heater; Inbuilt only; for residential installation, commer-
cial setting, or manufactured home; not designed for installation in a solid-fuel
burning fireplace
CSA certified according to ANSI Z21.88, CSA 2.33
Inbuilt convector, glass and steel fronted, ceramic log space heater with
forced convection and power flue system
Push button electronic / remote control
Flex line is 3/8 inch flare nut;
ball valve is 1/2 inch female x 3/8 inch flare
Electronic
Flame burners
Electronic thermostat
Ceramic
Electronic spark ignition
The flue must be terminated to atmosphere. Only flue components listed with
the appliance's certification can be used. Warranty will be voided if non-listed
components are installed.
AC 120V, 60 Hz
(134 to 212 CFM)
150 lb (68 kg)
79% NG; 81% LP (up to 83% with extended vent of 7.2 ft [2.2 m] and no
elbows)
Twin flue: maximum 6.5 ft with 2 elbows
Concentric: maximum 33 ft with 3 elbows
Natural Gas
4.3 in (109 mm) W.C.
10.5 in (267 mm) W.C.
Factory Set
Natural Gas: Low - 11,000 BTU/h; High - 29,000 BTU/h
Propane:
Low - 11,000 BTU/h; High - 28,000 BTU/h
Natural Gas: Low - 8,635 BTU/h; High - 21,900 BTU/h
Propane:
Low - 8,855 BTU/h; High - 21,840 BTU/h
Rinnai Corporation RHFE-750ETRA
Propane Gas
9.8 in (249 mm) W.C.
13.0 in (330 mm) W.C.
Factory Set