INSTALLATION

Step 6.
Positioning the Heater Engine
Before installing the heater, check it is labelled for the
correct gas type, (refer to the gas type label on the top
body panel of the heater). Refer to the local gas authority
for confirmation of gas type if you are in doubt.
Place the heater engine in front of the fireplace enclosure.
A panel from the cardboard packing carton
placed on the floor underneath the heater
will help prevent possible damage to
HINT
flooring.
Step 7.
Connect Electrical Supply
Ensure that the external isolation switch is OFF before
connecting the power to the heater engine.
Step 8.
Prepare Gas Supply
Remove the threaded brass plug from the S/S flexi pipe
consumer gas supply pipe.
Step 9.
Inserting Heater Engine & Connecting Flue
Spigot Plate
Position the heater engine so that the outer edges of the
spigot plate (F) can be aligned with the guide rails (M) on
to of the engine. Then carefully move the heater engine
into the fireplace ensuring that the gas supply pipe and
fittings (N) feed into the rear access hole and that the
outer edges of the spigot plate (F) engage the guide rails
(M).
Use two screw bolts (O) located in the upper flange of the
heater to engage the nutserts installed in the front tab of
the spigot plate (F).
Tighten these screw bolts, to pull the spigot plate (F)
forward and allows the 6 locating / locking tabs (P) of the
engine to engage the corresponding holes (Q) of the spigot
plate (F) and form a seal between the flue components
and the engine.
On completion of heater installation DO
NOT allow any portion of the 100mmØ
DANGER
exhaust flue to remain in contact with any
combustible materials. Flue temperature
may be hot enough to ignite certain
materials.
Take care that the electrical cord does not
bunch up or get pinched behind the heater
engine while inserting the engine.
CAUTION
Step 10. Securing The Heater Engine
Fasten the heater to the masonry work using appropriate
fasteners (not supplied) using the three holes across the
top of the fascia assembly mounting panel and the 3 holes
on each side of the side panels as shown (R).
Step 11. Connecting Gas
Continue to "CONNECTING GAS" on page 23.