Rasilient ApplianceStor 50 User Manual page 53

Performance storage server
Table of Contents

Advertisement

Hardware Installation
7. From the View menu, select Advanced Mode to display the details of the Intel Rapid Storage
Console.
8. From the Volumes view option, select RAID volume to view the rebuilding status. When
finished, the status is changed to "Normal".
Rebuilding the RAID with a new hard disk
If any of the SATA hard disk drives included in the RAID array failed, the system displays the status
of the RAID volume as "Degraded" during POST. You may replace the disk drive and rebuild the
RAID array.
To rebuild the RAID with a new hard disk:
Remove the failed SATA hard disk and install a new SATA hard disk of the same specification
1.
into the same SATA Port.
Select a destination disk with the same size as the original hard disk.
Reboot the system and then follow the steps in section Rebuilding the RAID with other non-RAID
2.
disk.
Setting the Boot array in the BIOS Setup Utility
You can set the boot priority sequence in the BIOS for your RAID arrays when creating multi-RAID
using the Intel® Rapid Storage Technology.
To set the boot array in the BIOS:
Set at least one of the arrays bootable to boot from the hard disk.
Reboot the system and press <Del> to enter the BIOS setup utility during POST.
3.
Go to the Boot menu and select the boot option priority.
4.
Use up/down arrow keys to select the boot priority and press <Enter>. See section 5.8 Boot
5.
menu for details.
From the Exit menu, select Save Changes & Exit, then press <Enter>.
6.
When the confirmation window appears, select Yes, then press <Enter>.
7.
User Manual
Rev. 1, November 2011
ApplianceStor
50
35

Advertisement

Table of Contents
loading

Table of Contents