Omron Microscan LVS 7000 Operation Manual page 90

Table of Contents

Advertisement

Bypass Button
Click the "Bypass" button to suspend any outputs (such as the stop motion signal) from the LVS-7000.
The screen flashes between yellow and white when activated in the settings (ShowStatusAlert =1), and the word
"Bypass" scrolls across the top, left corner of the screen indicating the system is in Bypass mode. All repeats
during Bypass appear in pink in the Reports\QC File Viewer.
IMPORTANT: The DontProcessDuringBypass setting (within the [System] section) in the LVS7000.ini file
allows you to configure the LVS-7000 to process or not process sectors during bypass.
Example LVS7000.ini file
[System]
ConsecutiveReadLines=5
CpuUtilizationWarning=75
DontProcessDuringBypass=0
ePedigree=0
See examples on next two pages.
LVS-7000 Operations Manual Version 5.6.X
LVS-7000 Operations Manual Version 5.6.X
Page 90 of 187