SkipAutoSetupShrink indicates whether rectangular borders around labels or space in-between labels are
detected when using Automatic Setup.
SkipAutoSetupShrink=0 (default). When drawing a sector around a label, the software
o
automatically detects rectangular borders around labels and space in-between labels.
SkipAutoSetupShrink=1 - When drawing a sector around a label, the software does not detect
o
rectangular borders around labels or space in-between labels. Sectors drawn become expanded
to fill a horizontal and vertical repeat. There are no gaps between labels.
SpotVoidCheck will error any spot anywhere within a barcode. Do not use unless instructed by an Omron
Microscan technician.
StripParentheses takes parentheses off decoded data strings from symbologies such as GS1 databar or
Data Matrix.
Strobe allows the system to be used in viewing mode like a strobe light. There must be a consistent sync
mark on the web to use this feature.
Strobe=0 allows the software to be used in its Normal mode.
o
Strobe=1 allows the software to be used in Strobe Mode.
o
Strobe=2 allows the software to be used in an Advanced strobe mode. Only use this setting if
o
advised by an Omron Microscan Technician.
TakeSecondPicture should only be configured by an Omron Microscan representative.
ThreadLockTimeout should only be configured by an Omron Microscan representative.
TiltedRead attempts to read a short in height barcode by applying a slight rotation.
TriggerStopMotionOnLearnBlemish tells the software to send a stop motion signal when a Blemish sector
has been defined. This helps to stop the Rewinder to visually inspect label(s) that are used as a Golden
image.
TriggerStopMotionOnLearnBlemish=0 – Feature is off.
o
TriggerStopMotionOnLearnBlemish=1 – Signal will be sent to stop Rewinder after Blemish sector
o
is defined or Golden Image is relearned.
TurretSignalDelay sets delay (in inches) from the moment the turret signal is received, until the Change
Roll on the fly command is activated.
UseBypassSignal turns on the monitoring of the Bypass signal Input line. Activated on LOW signal.
UsePhotoeyeSignal turns on the monitoring of the Photo optic signal Input line. Activated on LOW signal.
This is special as it can use any available port via the integer used. Also, the polarity can be switched by
making the integer a negative number. For example, UsePhotoeyeSignal=-3 makes it respond to an
active HIGH signal on input #3.
UseSectorTags
UseSectorTags=0 feature is off.
o
UseSectorTags=1 allows a sector's decoded information to be displayed above any thumbnail
o
referencing the tagged sector.
UseTurretSignal turns on the monitoring of the Turret Cutsignal Input line. Activated on LOW signal. It will
effectively stop logging for a roll and begin another.
[System]
A5Follows=34
AcceptReplaceInputTimer=0
AddMissingTriggers=0
AutoBreakRoll=0
AutoLogin=0
AutoMakeReady=0
AutoSetup=1
AutoSetup3Margin=1
AutoSetupSideMatch=32
AutoStop=0
Base64Trailer=0
BorderIndent=0