Error Code
!DU
Duplicate
!FG
Foreground
!GP
Gap
!MX
Matrix
MM!
Mismatch
!NA
Not Assessed
!NS
Not Synced
!NR
No Read
!QU
Quality
!RG
Range
!SQ
Sequence
LVS-7000 Operations Manual Version 5.6.X
A !DU appears when the character string has been read before in the job
that you are running. The Check for Duplicates option in the Matching
screen will enable this error.
This is a blemish error. The foreground (!FG) is defined in the blemish
sector setup. This means it is in the foreground portion of the sector.
When the system is triggered, the camera takes a picture of the label. The
system does not read any of the sectors within that image. The system
does not continue to increment the next expected record within the datafile.
The system logs to the report the !GP error code to the associated data.
Matrix searches the areas between labels for unstripped waste.
When the system is triggered, the camera takes a picture of the label. The
system reads all sectors within the image and compares to the associated
Job/Sector data in the datafile. One or more sectors do not match to what
the Job/Sector settings dictate that it should be. The system logs to the
report the data read from each sector attaching the MM! error code to the
associated sector's data.
Note: Mismatch only applies when comparing the data to a match source. If
running a Sequential type match, then a Mismatch error will be reported as
a Sequence error.
The incoming data is not being assessed due to a separate error.
The system has lost synchronization, and is therefore not processing any
data outside of looking for a re-sync lock. It will auto log this run portion as
"requested to splice"
When the system is triggered, the camera takes a picture of the label. The
system does not read/decode one or more sectors within the image. The
system compares to the associated Job/Sector data in the datafile. The
system logs to the report the data read from each sector attaching the !NR
error code to the associated sectors' data.
When the system is triggered, the camera takes a picture of the label. The
system reads all sectors within the image. The system compares to the
associated Job/Sector settings in the data file. If one or more
characters/barcodes within a sector are found to be outside the pre-
determined acceptable quality threshold, then the repeat is marked as an
error and displayed in red in the log file. The actual score is appended to
the end of the read data.
The associated datafile is loaded the system then reads the first and last
record in the sequential datafile. The system stores these values. When the
system is triggered the camera takes a picture of the label. The
system reads all sectors within the image. The system compares to the
associated record in the datafile. Not only did the record not match the
datafile, but it was also out of the range of numbers that the datafile
contains. The system logs to the report the data read from each sector
attaching the !RG error code to the associated sector's data.
When the system is triggered, the camera takes a picture of the label. The
system reads all sectors within the image. The system compares to the
associated Job/Sector in the datafile. One or more sectors are found to be
LVS-7000 Operations Manual Version 5.6.X