Alarm Matrix: Error Condition View
After all sectors have been established, you are prompted to determine an error condition. See the section below
entitled "Error Conditions" for more information.
Depending on the supplied hardware, the following relay outputs can be triggered by any of the listed error
conditions:
Line 1
Connected to the green light indicating a "good read." It is not connected to a relay
Line 2
Connected to the yellow light. It is not connected to a relay
Connected to the red light and a relay
Line 3
Line 4
Connected to the Stop Motion relay
The five columns on this screen are listed below:
Column
Condition
Code
Trigger
Dwell
Stop Motion
LVS-7000 Operations Manual Version 5.6.X
Lists the various error conditions that the system can detect.
Lists the abbreviation of the error conditions detected by the system and used
throughout the final reports. See the Troubleshooting section for more
information on error codes.
Lists any of the 4 Input/Output lines. Any listed error condition can be trained to
activate any I/O line by clicking on the appropriate row box; this will change the
path to another line. You can also choose "None".
Lists the duration of the output signal. You can choose from "10 ms" to "hold".
States when to activate the "Stop Motion" error condition. You can choose to
stop immediately or to not stop at all. Or, you can choose to stop after a certain
number of errors occur contiguously (from 1 to 10 errors in a row).
LVS-7000 Operations Manual Version 5.6.X
Description
Page 71 of 187
Need help?