6.4. Optional Interface for Compact 2 Basic Drives

6.4.1 Installation
The Ethernet/IP interface is mounted underneath the control pod.
 Remove the control pod as described in the Compact 2 installation guide.
 Locate the Ethernet/Ip interface in the slot below the control pod.
 Refit the control pod.
6.4.2 Layout

6.5. Drive Parameter Settings

6.5.1 Overview
The following parameter settings are required in the drive. For further description of the drive parameters, refer to the drive user guide.
Drive Type
Parameter
Drive Address
Modbus RTU Baud Rate
Modbus RTU Data Format
Communication Loss Reaction
Command Source Selection
www.invertekdrives.com
MAC Address shown here
P1: Primary Ethernet Port
P2: Secondary Ethernet Port
WARNING! Do not connect Ethernet cables to the
RJ45 port on the control Pod!
Optidrive E3 (ODE-3-...)
P-36 Index 1
P-36 Index 2
N/A
P-36 Index 3
P-12
Setting
1
1 15.2kbps
N-1
As required
Select for Fieldbus Control if control of the drive operation is required
Version 1.00 | Fieldbus Guide | 17