Assa Abloy Corbin Russwin Access 700 ED5000N Series Installation Instructions Manual page 6

Exit devices for 9700 tcpip1 & pwi1 series trim
Table of Contents

Advertisement

ED5000N Series Exit Devices For
9700 TCPIP1 & PWI1 Series Trim
3.
Trim Assembly Instructions:
a. Check cylinder components:
Cylinders longer than 1-1/8" (29mm) require collars.
Refer to Cylinder Collar Chart (Fig. 3a).
(for Mortise, skip to Step 5)
b. If required, modify by cutting cylinder tailpiece:
Correct length is 1/16" to 3/16" (2 to 5mm)
beyond cylinder housing cam.
c. Assemble cylinder:
1. Insert cylinder housing prongs into matching notches of escutcheon.
2. Pass cylinder tailpiece through cylinder collar (if required) and slot in cylinder cam.
3. Fasten cylinder in escutcheon recess or collar using 2 mounting screws.
Do not overtighten screws.
d. Escutcheon Assembly (Fig. 3b):
The lever is handed (LHR shown).
Note: Lever Return Spring handing can be identified by the color of the spring:
LHR: Part Number 651F618 (Red)
RHR: Part Number 651F628 (Blue)
Cam must be postitioned as shown
when cylinder tailpiece is assembled
Copyright © 2018 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
5) Rim Exit Installation Instructions (Continued)
Escutcheon Assembly
Rim Cylinder
Cylinder Collar (if required)
*Specify Finish
Fig. 3b
6
Cylinder Collar Chart
Cylinder Length
Inches
Millimeters
1-1/8"
29mm
1-1/4"
32mm
1-1/2"
38mm
Fig. 3a
Cylinder Housing
Cam
Collar
None
422F88*
686F98*

Advertisement

Table of Contents
loading

This manual is also suitable for:

Corbin russwin access 700 ed5000s series