ML20600 TCRNE1 Series
M802 125 kHz Reader Option
Mortise Lockset
Attention Installer
FM292 10/18
WARNING
This product can expose
you to lead which is
known to the state of
California to cause cancer
and birth defects or other
reproductive harm. For
more information go to
www.P65warnings.ca.gov.
08/2018
Copyright © 2017 Corbin Russwin, Inc. All rights reserved.
Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.

Advertisement

loading

Summary of Contents for Assa Abloy Corbin Russwin Access 600 ML20600 TCRNE1 Series

  • Page 1 Installation Instructions ML20600 TCRNE1 Series M802 125 kHz Reader Option Mortise Lockset FM292 10/18 Attention Installer Please read these instructions carefully to prevent missing important steps. Please Note: Improper installations may result in damage to the lock and void the factory warranty. Important: The accuracy of the door preparation is critical for proper functioning and security of this lock.
  • Page 3: Table Of Contents

    ML20600 Series Mortise Lock Table of Contents 1) Warning ................3 2) General Description .............4 3) Features ................4 4) Regulatory Specifications ...........4 5) Product Illustration .............5 6) Wiring Diagrams ..............6 7) Installation Instructions ............8 8) Operational Check .............18 1) Warning Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
  • Page 4: General Description

    ML20600 Series Mortise Lock 2) General Description The Corbin Russwin Access 600 TCRNE1 Series mortise lock is designed to interface with existing Wiegand Electrical Access Control (EAC) panels. The reader requires 12VDC for power and is available with 125 kHz HID proximity technology.
  • Page 5: Product Illustration

    ML20600 Series Mortise Lock 5) Product Illustrations Item Part Number Description Req. 752F602 26D Mortise No Cyl/ No TP Function (ML20607) 752F612 26D Mortise Cyl/ No TP Function (ML20606) 752F622 26D Mortise Cyl/ with TP Function (ML20608) 752F632 26D Mortise No Cyl/ with TP Function (ML20609) 816F008 ML20606/ML20607 Fail Safe (SAF) 816F018...
  • Page 6: Wiring Diagrams

    ML20600 Series Mortise Lock 6) Wiring Diagrams Product 8 PIN CONNECTOR 4 PIN CONNECTOR 1-Black 2-Red 3-White 4-Green 5-Orange 6-Blue 7-Brown 8-Yellow 1-Violet 2-Gray 3-Pink 4-Tan ACCESS CONTROL DEVICES: Access600 Mortise, ElectroLynx wire Color / Function assignments Corbin Russwin 12/24VDC WIE- WIE- EGND...
  • Page 7 ML20600 Series Mortise Lock 6) Wiring Diagrams (Continued) Typlcal ML20600 x M802 Series Lock Application Diagram (12/24VDC Lock) MODE 1: LED WIRE NOT USED = RED LED ON WHEN POWERED Standard Application Shown - For Alternative Applications Contact 1-800-810-WIRE (9473) Reader Electronics Require 12 or 24VDC UL294 Listed, Power Limited Power Supply (or UL603) 12VDC System with 12/24VDC (Lock body) Reader Draw = 150mA...
  • Page 8: Installation Instructions

    ML20600 Series Mortise Lock 7) Installation Instructions Verify Hand and Bevel of door. Illustrations shown are as viewed from the outside or secure side of opening. Left Hand Left Hand Right Hand Right Hand Hinges Left. Reverse Bevel Hinges Right. Reverse Bevel Open Inward.
  • Page 9 ML20600 Series Mortise Lock 7) Installation Instructions (Continued) Handing of Lock Body: If necessary re-hand latch and move RED locking screw to side of lockbody to side of lock body to be locked: a. Push in latch while gently pushing on catch plate with screwdriver (Fig. 3a). b.
  • Page 10 ML20600 Series Mortise Lock 7) Installation Instructions (Continued) Install Lock Body into Door: a. Feed wires through 1-5/16” diameter hole on INSIDE of door while installing lock body (Fig. 4a). b. Pull wires through hole while inserting lockbody. DO NOT push wires back into cylinder hole (Fig. 4b). Important: Door must remain open during installation.
  • Page 11 ML20600 Series Mortise Lock 7) Installation Instructions (Continued) Install Cylinder: a. Thread cylinder into lock body (Fig. 6a). Note: Make sure cylinder is oriented correctly (Fig. 6a1). b. Tighten cylinder clamp using 7/64” allen wrench (provided) (Fig. 6b). c. Turn the key to make sure that lock functions correctly (latch, deadbolt, and key). Fig.
  • Page 12 ML20600 Series Mortise Lock 7) Installation Instructions (Continued) Install Mounting Screws: a. Tighten two screws installed at Step 5. 4 - Pre-drilled 1/8” Tighten Screws Diameter Holes b. Install 4 surface mount (#8 x ¾” combination screws) into pre-drilled 1/8” diameter holes. Fig.
  • Page 13 ML20600 Series Mortise Lock 7) Installation Instructions (Continued) Install Inside Eschutcheon: a. Attach connectors according to previous instructions. b. Feed excess ElectroLynx and reader wires into door prep. c. Tuck excess body wire harness under escutcheon. Do NOT push back into door prep. d.
  • Page 14 ML20600 Series Mortise Lock 7) Installation Instructions (Continued) Inside Face of Door 10a. Install Standard Lever Trim. Refer to 10b on following pages for Muséo Trim: Step 1a Step 1b Outsode Face of Door Inside Face of Door Outsdide Adapter Plate Fig.
  • Page 15 ML20600 Series Mortise Lock 7) Installation Instructions (Continued) Step 4 Use Correct Spindle Orientation Inside Face of Door STANDARD MUSÉO Good Lever Fig. 4b kƒ„ƒ· Fig. 4a Step 5 Align adjustment bolt with threaded hole in lever Align adjustment bolt with threaded hole in lever Adjustment bolt needs...
  • Page 16 ML20600 Series Mortise Lock 7) Installation Instructions (Continued) 10b. Install Muséo Trim: Step 1 Unthread hub 1/2 turn then push spindle into lever Thread hub into lever using spindle until snug Step 2 Inside Face of Door Outside Face of Door Copyright ©...
  • Page 17 ML20600 Series Mortise Lock 7) Installation Instructions (Continued) Install Armored Front: a. Tighten (2) screws through lock body. b. Attach armored front with two #8 x ¼” screws (Fig. 11). Outside Face of Door Tighten Armored Front (2) #8 x 1/4” Fig.
  • Page 18: Operational Check

    Wiegand Test Unit 12 or 24VDC solenoid lock voltage adjustable The ASSA ABLOY Wiegand Test Unit verifies your installation in the field. The test unit checks for proper wiring, card reader data Operates as Fail Safe or integrity, lock functionality including lock/unlock, door position Fail Secure status, and request-to-exit (REX) status.
  • Page 20 Fax: 800-447-6714 corbinrusswin.com Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. Patent pending and/or patent - www.assaabloydss.com/patents.