4. Install Batteries and Battery Cover
Before installing batteries for the first time:
a. Remove pull tab from its position beneath the coin cell by pulling on tab in direction
of arrows printed on tab (Fig. 15a).
b. Place (6) "AA" alkaline batteries in the compartment, being careful to align
polarity properly.
c. After batteries are installed, there is a slight delay; then an audible "beep" will
sound and the lock motor will cycle.
d. Secure cover with (2) security screws utilizing T-20 security torx driver (Fig 15b).
For battery replacement:
When replacing the (6) "AA" alkaline batteries in the compartment, please note
batteries must be replaced within five (5) minutes to prevent the internal clock from
becoming inaccurate.
Fig. 15a
Copyright © 2018 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
9) PWI (Wireless) Wiring & Installation (Continued)
Coin Cell Pull
Tab
Fig. 15b