Assa Abloy Corbin Russwin Access 700 ED5000N Series Installation Instructions Manual page 25

Exit devices for 9700 tcpip1 & pwi1 series trim
Table of Contents

Advertisement

ED5000N Series Exit Devices For
9700 TCPIP1 & PWI1 Series Trim
4. Install Batteries and Battery Cover
Before installing batteries for the first time:
a. Remove pull tab from its position beneath the coin cell by pulling on tab in direction
of arrows printed on tab (Fig. 15a).
b. Place (6) "AA" alkaline batteries in the compartment, being careful to align
polarity properly.
c. After batteries are installed, there is a slight delay; then an audible "beep" will
sound and the lock motor will cycle.
d. Secure cover with (2) security screws utilizing T-20 security torx driver (Fig 15b).
For battery replacement:
When replacing the (6) "AA" alkaline batteries in the compartment, please note
batteries must be replaced within five (5) minutes to prevent the internal clock from
becoming inaccurate.
Fig. 15a
Copyright © 2018 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
9) PWI (Wireless) Wiring & Installation (Continued)
Coin Cell Pull
Tab
Fig. 15b
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Corbin russwin access 700 ed5000s series

Table of Contents