Table 1-3 Alarm Report Definitions; Table 1-4 Alarm Report Item Definitions - NEC SL1000 Features And Specifications Manual

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

SL1000
<< Alarm Report
LVL
NO
MAJ
0006
MAJ
0006
MIN
0068
MIN
0068
MIN
0068
MIN
0068
A
Alarm Report Heading
LVL
NO
STAT
DATE
TIME
ITEM
UNIT
SLT
PRT
PARAMETER
PKG Installation
ISDN Link
CPU LAN Link
Blocking
System Data Change
System Start Up
SMDR Link
STA
TRK
System Information
The system can print a report of the units installed, the port assignments, and the port types. This
information is sent to the extension defined in Program 90-13.
The System Information Reports indicate:
• Date and Time of the Report
• Unit names
1-22
STAT
DATE
ERR
05/16/06
REC
05/16/06
ERR
01/22/09
ERR
01/22/09
ERR
01/22/09
ERR
01/22/09

Table 1-3 Alarm Report Definitions

Alarm Type (MAJ = Major, MIN = Minor)
Number of Alarm (4-digit)
Status (REC = Recovered, ERR = Error, WAR = Warning
Date the Alarm Occurred
Time the Alarm Occurred
Name of the Alarm
Name of the Unit
Chassis Slot Number
Chassis Port Number
Related Information

Table 1-4 Alarm Report Item Definitions

Item Name
Unit is removed or inserted.
ISDN Line failure is detected.
CPU LAN connection failure is detected.
Terminal Failure may have occurred because terminal blocking is detected.
Terminal is unplugged or wire is disconnected.
System Upgrade performed or Programming change.
System is reset.
Connection failure is detected between the CPU and SMDR printer device.
DSP for IP Station CAll were all busy.
DSP for Trunk Call were all busy, includes SIP trunks.
05/16/2006 14:30 PAGE 001
TIME
ITEM
UNIT
15:05
Blocking
15:07
Blocking
09:30
VoIP All DSP
VoIPDB
Busy
09:31
VoIP All DSP
VoIPDB
Busy
09:35
VoIP All DSP
VoIPDB
Busy
09:40
VoIP All DSP
VoIPDB
Busy
SLT
PRT
PARAMETER
ESIB
01
07
ESIB
01
07
01
00
01
00
01
00
01
00
Definitions
Definition
Alarm Reports
ISSUE 1.0
STA
TRK
LNK
NET