Program
Number
20-15-01
Ring Cycle Setup - Normal Incoming Call on
Trunk
20-15-03
Ring Cycle Setup - Incoming Internal Call
20-15-05
Ring Cycle Setup - DID/DDI
80-03-01
DTMF Tone Receiver Setup - Detect Level
80-03-02
DTMF Tone Receiver Setup - Start delay time
80-03-03
DTMF Tone Receiver Setup - Min. detect level
80-03-04
DTMF Tone Receiver Setup - Max. detect level
80-03-05
DTMF Tone Receiver Setup - Forward twist level
80-03-06
DTMF Tone Receiver Setup - Backward twist level Type 1 ~ 5 = 0 (1dBm)
80-03-07
DTMF Tone Receiver Setup - ON detect time
80-03-08
DTMF Tone Receiver Setup - OFF detect time
80-04-01
Call Progress Tone Detector Setup - Detection
Level
80-04-04
Call Progress Tone Detector Setup - No tone time Type 1 (DT) = 132 (3990ms)
Operation
Refer to the individual features listed in the Related Features section above in this feature.
Features and Specifications Manual
Program Name
Default
2
8
8
Type 1~5 = 0
Type 1~5 = 0
Type 1 = 10 (-20dBm)
Type 2 = 15 (-25dBm)
Type 3 = 10 (-20dBm)
Type 4 = 10 (-20dBm)
Type 5 = 10 (-20dBm)
2 (-2dBm)
Type 1 ~ 5 = 5 (6dBm)
Type 1 = 1 (30ms)
Type 2 = 1 (30ms)
Type 3 = 1 (30ms)
Type 4 = 1 (30ms)
Type 5 = 1 (30ms)
Type 1 = 1 (30ms)
Type 2 = 1 (30ms)
Type 3 = 1 (30ms)
Type 4 = 1 (30ms)
Type 5 = 1 (30ms)
Type 1 (DT) = 0 (-25dBm)
Type 2 (BT) = 0 (-25dBm)
Type 3 (RBT) = 0 (-25dBm)
Type 4 = 0
Type 5 = 0
Type 2 (BT) = 132 (3990ms)
Type 3 (RBT) = 132 (3990ms)
Type 4 = 0
Type 5 = 0