NEC SL1000 Features And Specifications Manual page 410

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

SL1000
Network
Screen Resolution
• You can have a maximum of four users logged into WebPro same time.
• You can have up to two phones in programming mode same time.
• You can have total of four users in programming mode at same time. This can be a any mix of Tele-
phone programming user and Webpro user as long as it wont exceed four users.
• Only One user can be logged into PC PRO. While user is logged into PC PRO Webpro, Telephone
programming couldnt be used.
• When programming via WebPro/PCPro, it requires you to logout before the system fully applies the
P
changes.
• In the System Data configuration window, you can open/close the system data by clicking the system
data you want to open/close.
• Some programs may needs the system to reset/reboot order for the system to effect the change that
been made. These Programs are: 10-12-01, 10-12-02, 10-12-03, 10-12-04, 10-13-01, 10-13-02, 10-
13-03, 10-14, 10-15, 10-16-01, 10-16-02, 10-16-03, 10-16-04, 20-01-03, 47-01-01, 80-01, 80-02-01,
80-02-02, 80-02-03, 80-02-04, 80-03, 80-04, 84-03-01, 84-03-02, 84-03-06, 84-03-07, 84-03-08, 84-
05-01, 84-09 and 84-10.
• When uploading the system. if the system has a MEMDB installed you must upload the file that was
taken from MEMDB or upload the flle that is for MEMDB.
Default Settings
None
System Availability
Terminals
None
Required Component(s)
PCPro apilication to use PCPro.
Web Browser to use WebPro.
For requirement check "Condition".
Related Features
None
Guide to Feature Programming
Program
Number
10–12–01
10–12–02
10–12–03
1-402
Item
Program Name
CPU Network Setup - IP Address
CPU Network Setup - Subnet Mask
CPU Network Setup - Default Gateway
Requirement
IP connection to the KTS
800 x 600 (minimum)
1024 x 760 (recommended)
192.168.0.10
255.255.255.0
0.0.0.0
ISSUE 1.0
Default
PC Programming