5) Connect the machine to the electricity network.
• Before installing the appliance, make sure any pre-existing electrical systems comply with the law and
correspond to the specifications shown on the ID plate of the appliance being installed (V, kW, Hz, and
available power).
• The appliances are supplied with a power cable 200 cm long with standard Schuko 16A plug; the outlet
must have a 10A fuse and must be easily accessible.
ELECTRICAL HAZARD!
The phase inversion in the three-phase machines must only be performed by qualified
technicians. Make sure the mains to which the machine shall be
connected to has a suitable and efficient earthing system. Verify that the
power cable is not damaged or stuck., Contact a qualified technician, in
case it must be replaced. Only qualified technicians must have access live
parts. Insert and remove the plug by pulling the plug itself and not the wire.
WARNING!
Make sure the plug is accessible even after the unit has been installed!
If the appliance plug is not easily accessible, the power mains must be equipped with devices for
complete disconnection, with a gap between the contacts allowing complete disconnection in
category III overvoltage conditions. If the entire length of the cable is not used, DO NOT roll it up
but leave it free and make sure it does not obstruct or endanger passers-by.
Make sure the power cable does not come into contact with any liquids, sharp or hot objects and
corrosive substances.
Do not allow children or animals to play with the power cable.
6) How to connect the Gas bottle
(per IDEA31 – IDEA 41 e IDEA 32 HiLine – IDEA 42 HiLine)
Use a suitable pipe Ø10mm, grafting it through the quick
coupling on the rear, to connect the appliance to the gas bottle.
Press the quick coupling green ring and insert the pipe. Adjust the
inlet pressure of reducer supplied together with the bottle,
between 0,5 and 1 bar.
_______________________________________________________________________________________
ORVED S.P.A Rev.01 – 09/2019 – cod. 1500735-00EN – User Manual for
IDEA
vacuum packing machines
Pag. 62 a 76
WARNING!
Contact the Food Gas supplier, to require the gas mix most responding to your needs and the
pressure reducer. Strictly comply with the gas manufacturer's instructions for proper use of the gas
cylinders and gas pressure reducers.
Use a suitable pipe, to connect the gas bottle to the vacuum machine. The most common pipe
is external Ø 10mm.
Use hose clamps to fix properly the pipe to the pressure reducer. Use only nitrogen
dioxide
(CO
), nitrogen and carbon dioxide mixtures
2
Do not use oxygen
(O
), other explosive or flammable gases, gas mixtures containing oxygen
2
or other explosive, flammable, or not suitable for foodstuff packing gases.
Fix the gas bottles firmly, to avoid them to overturn.
7) Clean the vacuum chamber and lid before use.
8) Check the absorption using an ammeter.
9) Run at least one complete vacuum packaging cycle for bags.
10) Inform the client of the exact use of the appliance, with specific reference to the use and requirements
of the client themselves.

17 Maintenance

WARNING!
Do not replace the Teflon when the bar is still hot, due to the risk of burns!
Remove always the plug from the socket before any maintenance intervention.
DANGER!
It is prohibited to remove the guards and safety devices in order to carry out maintenance
operations. Orved S.p.A. declines all liability for accidents due to non-compliance with the
above-mentioned obligation.
WARNING!
Always use suitable preventive measures and protective clothing (gloves, etc.) for any
maintenance and/or repairs. Only qualified technicians must perform maintenance or access live
parts of the machine as specified in this chapter.
Only original spare parts must be used and requested: spare parts that are not type-approved
could damage the appliance or cause physical injury.
Always cite the machine model and serial number (as per §17.3), when contact the technicians.

17.1 Replacement of complete sealing bar

• Extract the sealing bar from the vacuum chamber by lifting it horizontally from the sides (Fig. 1).
• Clean the electrical contacts and the pins drill holes (B) on the sealing bar thoroughly.
• Insert the new one, making sure the bar is properly engaged with the electrical contacts (A).
_______________________________________________________________________________________
ORVED S.P.A Rev.01 – 09/2019 – cod. 1500735-00EN – User Manual for
(N
), carbon
2
(N
and CO
) or other inert gas mixtures.
2
2
(O
IDEA
vacuum packing machines
Pag. 63 a 76
)
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Idea 40Idea 31Idea 41Idea 32 hi-lineIdea 42 hi-line