WARNING! In appliances provided with gas injection system, IT IS FORBIDDEN TO USE GAS MIX
CONTAINING OXYGEN IN A PERCENTAGE HIGHER THAN 21%, OR OTHER EXPLOSIVE AND
INFLAMMABLE GASES. The gas mixtures must be adjusted by the supplier at its place, or by
authorized technician, at the installation where the machine is used. Supplying and installation of
the gas bottle is reserved to supplying company qualified personnel.
WARNING! The vacuum packing machine was designed and projected to operate vacuum in
bags and hard containers. The maximum frequency of standard complete vacuum cycles
(vacuum and sealing) is 60 seconds.
WARNING! Stop the machine immediately, in case of gas leaks, due to defective or oxidized
connections as well as damaged pipes.
Contact the nearest service centre, for immediate replacement of damaged parts.
CAUTION! The room temperature should not fall below than +10°C, to avoid the pump oil
thickening, which could compromise the pump functioning.
CAUTION! The pump oil has to be checked constantly, through the sight glass (on the side or on the
machine rear panel). The correct oil level is in the range within MINIMUM and MAXIMUM. The colour
has to be clear and no turbidity.
CAUTION!
VACUUM PUMP OIL, MUST BE REPLACED PERIODICALLY; THE OIL CHANGE FREQUENCY,
INCREASE PROPORTIONALLY TO THE VACUUM MACHINE USE. THE OIL MUST BE CHANGED AT LEAST
EVERY 5.000 VACUUM CYCLES OPERTED. AT THE OIL CHANGE, THE EXHAUST FILTER MUST BE
REPLACED, TOO (see SCHEDULED ROUTINE MAINTENANCE table at Chapter 14).
In case the machine is used to vacuum pack liquids or humid products, the oil and the filter have
to be changed more often; in addition, in this case, it is necessary to change oil and filter after an
inactivity time longer than one month.
Before an inactivity time longer than two months, operate an oil change.
A whitish and cloudy, or dark and transparent oil colour, means respectively: suction of liquids and
humidity, or the oil age. The digital models are provided with oil change signal system. Once the
maximum number of cycles has been reached, at the switching on the message "ALL OIL" will
appear on the display. The number of vacuum cycles operated, can be detected at any time,
using the command panel.
It is really important to operate the pump dehumidification cycle (H2Out) periodically (see
chapter 13).
WARNING! DO NOT touch the sealing bars soon after sealing the bags, as they could be still hot.
_______________________________________________________________________________________
ORVED S.P.A Rev.01 – 09/2019 – cod. 1500735-00EN – User Manual for
IDEA
vacuum packing machines
Pag. 8 a 76
CAUTION! DO NOT remove the Teflon band covering the sealing bar; Do not use knives or any
different sharp tool to remove residuals from sealing bar. Wait for the sealing bar to cool down
completely, before any intervention (with not sharp and not pointed tools)
CAUTION! Clean the machine thoroughly after use: use a clean soft cloth moistened with water
(do not use any detergent or solvent) to clean the lid. For stainless steel parts, use specific
products. Do not use any water jet or steam, which could damage the appliance electric parts.
For any issue may arise (defective functioning or technical assistance) Contact our technical
customer service.
_______________________________________________________________________________________
ORVED S.P.A Rev.01 – 09/2019 – cod. 1500735-00EN – User Manual for
IDEA
vacuum packing machines
Pag. 9 a 76