5 BEFORE USING THE VACUUM PACKING MACHINE

Before using the machine, the vacuum chamber and lid must be cleaned using a clean, soft cloth soaked
in potable water.
It is recommended not to use aggressive detergents, stainless steel scrubbers, scrapers or abrasive, acidic
or aggressive substances, which may permanently damage the internal surfaces of the vacuum
chamber.
6 Command panel: Idea 30 – idea 40 – idea 31 – idea 41
_______________________________________________________________________________________
ORVED S.P.A Rev.01 – 09/2019 – cod. 1500735-00EN – User Manual for
IDEA
vacuum packing machines
Pag. 10 a 76
DESCRIPTION
Pressed contemporarily with STOP for 4", displays the number of vacuum cycles operated
1
Pressed contemporarily with STOP at turning on, allows to activate or deactivate the acoustic signal
Allows to set the vacuum level, the additional vacuum, Gas (only on IDEA31 - IDEA41)
2
If pressed after reaching the 90% of vacuum, it allows to anticipate the GAS injection
Scroll down the programs
3
Change the parameters values
4
Pressed contemporarily for 4", allow the saved program reset, restoring the factory values.
Allows to set the sealing time
5
Pressed during the vacuum cycle, allows to anticipate the sealing
stand-by/on and on/stand-by (pressed for 5")
Pressed contemporarily with PLAY/PAUSE for 4" displays the number of vacuum cycles operated
6
Pressed contemporarily with PLAY/PAUSE at turning on, allows to activate or deactivate the acoustic
signal
Interrupts the current vacuum cycle
7
Displays the current function
Displays the active program
Displays the active function and the set value
8
Displays any alarm
Displays the vacuum cycles operated before the oil change
9
If ON, indicates that the GAS function is active

6.1 Functions and warnings

6.1.1 Maximum admissible values

FUNCTION
VACUUM
ADDITIONAL VACUUM
SEALING
GAS (
IDEA31 - IDEA41)
CAUTION!
It is necessary to carry out preliminary tests, to identify the optimal percentage of GAS to be
injected, for every single product to be packed.

6.1.2 Factory configuration

FUNCTION
VACUUM
ADDITIONAL VACUUM
SEALING
GAS (
IDEA31 - IDEA41)
6.1.3 Activate / deactivate the acoustic signal
_______________________________________________________________________________________
ORVED S.P.A Rev.01 – 09/2019 – cod. 1500735-00EN – User Manual for
VALORE
10% – 99%
1 – 60 sec
0,1 – 6,0 sec
1 – 90%
VALORE
99
5 sec
2,5 sec
OFF
(
per
idea 30 – 40
-
Idea 31 – 41)
IDEA
vacuum packing machines
Pag. 11 a 76

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Idea 40Idea 31Idea 41Idea 32 hi-lineIdea 42 hi-line

Table of Contents