Fan - Cafection Encore Ground Service & Installation Manual

Hide thumbs Also See for Encore Ground:
Table of Contents

Advertisement

SERVICE & INSTALLATION MANUAL for Cafection's Encore Ground
www.cafection.com
Brew Group Assembly Sanitizing Treatment
Frequency: quarterly or every 5,000 cycles
Regular sanitation treatments of the brew group assembly prevent residue from affecting
the vacuum in the mechanism and altering the taste of the beverages.
Please refer to the section 7.2 of this manual for sanitizing instructions.
7.8.3

Fan

Frequency: quarterly or as needed
Visually inspect the fan located directly to
the right of the hot chocolate canister and
clean it if needed.
1. Turn off the unit and unplug it to stop
2. Unplug the fan and remove the guard
3. Wipe the fan clean with a dry
4. Reinstall the guard, plug the fan and
ENCORE GROUND Rev. 0 2017-04
800-561-6162
the fan.
to access the fan blades.
disposable towel.
the machine in and turn the brewer
back ON.
Fan
63