SERVICE & INSTALLATION MANUAL for Cafection's Encore Ground
www.cafection.com
Move 3
Position where the piston stops before dispensing the coffee into the cup.
A setting too high will prematurely open the brew chamber, causing a mess of wet
coffee grounds inside the machine.
A setting too low will not pull all coffee through the filter.
This setting must be changed with care.
Pause 3
Pause time before the brew chamber opens. If there are wet coffee grounds on the filter paper
at the end of the cycle, increasing this setting might solve the issue. 20 units = 1 second.
Pause 4
Brew group drain time. This setting must be high enough to empty the brew group at the
end of the cycle. 20 units = 1 second.
This interface is used to set all coffee drinks' brew cycles. There is no individual
setting table per recipe.
Automated Fast Settings of All Drinks Interface
1
2
4
3. This table is used to set the quantity of soluble powder (in grams) per water once.
4. These buttons are used to assign the settings to a cup size (small, medium and large).
The fast settings does not affect the Iced Coffee, Long Espresso, Energy Shot,
Hot Shot Blend, Café Latte and Cappuccino drinks recipes, which can only be
edited manually.
ENCORE GROUND Rev. 0 2017-04
800-561-6162
3
All drinks will automatically be set under the Liquids & Ingr. subtab.
1. This section is used to select desired cup
size. Slide the coffee cup icon from 7 oz to
20 oz.
2. This table is used to set the quantity of
coffee (in grams) per water once.
41
Need help?
Do you have a question about the Encore Ground and is the answer not in the manual?
Questions and answers