Brew Group Assembly Sanitizing Treatment
Frequency: quarterly or every 5,000 cycles
Regular sanitation treatments of the brew group assembly prevent residue from affecting
the vacuum in the mechanism and altering the taste of the beverages.

Fan

Frequency: quarterly or as needed
Visually inspect the fan located directly to
the right of the hot chocolate canister and
clean if needed.
1. Turn off the unit and unplug it to stop
the fan.
2. Unplug the fan and remove the guard
to access the fan blades.
3. Wipe the fan clean with a dry
disposable towel.
4. Reinstall the guard, plug the fan and
the machine in and turn the brewer
back ON.
www.cafection.com