www.cafection.com
8.2

Brew Group Assembly

Preventive maintenance: yearly or every 25,000 coffee cycles
The brew group is the heart of the equipment and is responsible for the taste of every cup. It needs
to be serviced regularly to maintain the quality of the beverages served.
Cafection offers a Brew Group Exchange Program. This program ensures a constant running of
the machine by receiving a replacement brew group to use while maintenance is performed on
the actual brew group of the unit. Cafection will completely clean and replace all parts requiring
maintenance, including the screen and seal, the cylinder and the piston seal.
The cleaned brew group will be returned with a one (1) year warranty on defective parts.
Contact salesorder@cafection.com or 800-561-6162, ext. 311, to order parts or for additional
information.
Inspection
Frequency: monthly
The following are signs that the
coffee extraction is not being
performed adequately and that
the brew group may require
preventive maintenance:
- Seal is damaged.
- Air gets into the cylinder from
around the piston seal and
creates bubbles in the coffee.
- There are coffee grounds in the
coffee dispensed.
- Spent coffee grounds remain
wet on the filter paper.
ENCORE GROUND Rev. 0 2017-04
800-561-6162
Cylinder
Piston
seal
Screen and seal
Brew chamber
65