SOFTWARE CHANGE
Program change can only be performed using a microSDHC memory card.
Note: The software may only be replaced by an authorized person in
compliance with all electric shock precautions!
To change the program, disconnect power to the control panel. Insert the memory card
into the marked slot on the panel.
The new software should be stored on the memory card in * .pfc format in the form of
two files: a program file in the control panel and a program file for driver module A.
Insert the new software directly on the memory card without saving the data in a
subdirectory. Then connect the mains supply to the controller and enter the menu:
General settings
controller, then in the controller panel and other devices.
OTHER FUNCTIONS
Power failure
In case of a power failure, the controller returns to the operating mode it was in before the
power failure.
Freeze protection
When the boiler temperature drops below 5 ° C, the boiler pump is activated, which forces
the boiler water circulation. If the water temperature does not rise, the boiler burner is
switched on.
Note: This function cannot be the only frost protection during installation! Other
methods should be used. The controller manufacturer is not liable for any related
damages.
Program update and replace the program first in module A of the