Boiler regulation with room thermostat
In this case, the boiler will be regulated by a room thermostat, which will be connected to
the contacts of the electronics terminal board. The control function according to the room
thermostat must be selected in the boiler electronics. The boiler will also take into account
the set boiler temperature. Instead of a room thermostat, another type of heating
requirement can be installed, such as e.g. boiler control via internet.
Boiler protection
Boiler is equipped with emergency thermostat. If the boiler temperature exceeds
110°C, boiler safely gets out of order. When the boiler temperature decreases, it is
possible to start the boiler again by using the reset button placed on the back panel.
Fuel refill
Fuel is added to the fuel tank, which can be purchased as an optional accessory to the
boiler. The principle is that refueling should take place before the supply of pellets in this
tank is consumed. In the electronics it is possible to set the function of checking the
amount of fuel in the tank. Based on this setting, it is possible to display the current
amount of pellets in the tank on the boiler display.
ATTENTION! Fuel container can be open only when fuel is being refilled,
eventually by cleaning. Container has to be closed during the boiler operation.
Ash removing
The ATTACK PELLET 30 AUTOMATIC Plus boiler is equipped with device for
automatic ash re-moving into the detachable box. It is necessary to check the box 2x per
season and to empty it, if necessary. The space of the bottom of the combustion chamber
must be cleaned after the end of the heating season. Stop the boiler for a short time, when
removing the ash container.
When emptying the box (see the picture):
1.Close inlet opening into the container by pulling the lever on the container rear side fully
to the left
2.Release lever catches on container sides
3.Detach container from inlet tube of door cover by pulling it to yourself
4.Remove the ash