Caution - the cross-section of the wires for connecting the ecoSTER TOUCH
panel must be at least 0.75 mm2
The maximum cable length for the panel is 30 m. The cross-section of the cables must not
be less than 0.5 mm2.
Three-wire connection
Connect according to the wiring diagram.
Two-wire connection
The two-wire connection requires a 5 VDC or 12 VDC supply, and a rated current of at least
400 mA. GND and VCC wires at the output of the ecoSTER TOUCH connected to an external
power supply. Power supply is not part of the controller delivery. Connect the D + and D-
wires as shown in the diagram.
Cooperation with web module
The controller can work with the ecoNET300 internet module. It allows the user to view
and control the boiler online via WiFi or LAN using the website www.econet24.com via a
web browser or a conveNOnt application for mobile devices:
ecoNET.apk(Android)