Eps-C2 Redundant Power Supply Technical Specifications; Rps-90 Redundant Power Supply Technical Specifications - Extreme Networks ExtremeSwitching X440-G2 Series Hardware Installation Manual

For switches using extremexos 21 or 22
Hide thumbs Also See for ExtremeSwitching X440-G2 Series:
Table of Contents

Advertisement

Table 276: Power Specifications
Voltage input range
Nominal input ratings
Maximum inrush current
Output
Power supply input socket and cord
Power cord wall plug
Efficiency
Table 277: Environmental Specifications
Operating temperature
Storage temperature
Operating humidity
Operational shock

EPS-C2 Redundant Power Supply Technical Specifications

The following tables list the specifications for the EPS-C2 redundant power supply unit (model 10936).
Table 278: Physical Specifications
Dimensions
Weight (unit only)
Table 279: Other Specifications
Allowable PSU
Power cord input plug/socket
Power cord gauge

RPS-90 Redundant Power Supply Technical Specifications

The following tables list the specifications for the RPS-90 redundant power supply unit (model
RPS-90).
ExtremeSwitching and Summit Switches: Hardware Installation Guide
100-127/200-240
47 to 63Hz
12.5 A max at 115VAC and 6A max at 230VAC at Full 770 W load
45A at Max 264 VAC at 25C with cold start
54 V, 13.2 A max, 770 W
IEC/EN 60320-1/C16 AC input receptacles
Refer to
Power Cord Requirements for AC-Powered Switches and AC
Power Supplies
on page 393.
Minimum efficiency: 88% at maximum power output.
-10°C to 50°C (normal operation)
-40°C to 70°C
93% relative humidity, non-condensing at 30C
2
30 m/s
(3 G)
4.4 cm H x 44.1 cm W x 38.4 cm D
1.73 in H x 17.4 in W x 15.1 in D
1.03 kg (2.27 lb)
Summit 750W PoE AC PSU
IEC 320 C13/C14
Min 18AWG
Technical Specifications
383