Table 153: Power Specifications
Switch Model
X590-24t-1q-2c
X590-24x-1q-2c
Table 154: Power and Heat Dissipation
X590-24t-1q-2c-AC
X590-24t-1q-2c-DC
X590-24x-1q-2c-AC
X590-24x-1q-2c-DC
CPU, Memory
CPU/Memory
1GHz 64-bit CPU
2GB DDR3 ECC SDRA memory
4GB eMMC Flash Memory
12 MB buffer, per chip
Standards and Environmental Data
Table 155: Safety Standards
North American Safety of
ITE
European Safety of ITE
International Safety of ITE
12
Minimum is defined as idle, with no ports linked. Maximum is defined as fans high, all ports 100% traffic.
ExtremeSwitching and Summit Switches: Hardware Installation Guide
AC Input: 100-127 VAC, 2.5 A max. per PSU, 50/60 Hz
AC Input: 200-240 VAC, 1.25 A max. per PSU, 50/60 Hz
DC Input: -48 to -60 VDC, 5.0 A max. per PSU
12
Minimum
Heat
Minimum
Dissipation (1 PSU)
Consumption
310.97 BTU/hr
91.14 W
332.63 BTU/hr
97.49 W
278.42 BTU/hr
81.60 W
286.61 BTU/hr
84.00 W
UL 60950-1 2nd Ed., A2:2014, Listed Device (US)
CSA 22.2 #60950-1-07 2nd Ed., 2014-10 Canada)
Complies with FCC 21CFR 1040.10 (US Laser Safety)
CDRH Letter of Approval (US FDA Approval)
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 2nd Ed.
EN 60825-1:2007 IEC 60825-1:2007 Class 1 (Lasers Safety)
2014/35/EU Low Voltage Directive
CB Report & Certificate per IEC 60950-1:2005+A1:2009+A2:2013 + National
Differences
AS/NZX 60950-1 (Australia /New Zealand)
Technical Specifications
12
12
Power
Maximum
Heat
Dissipation (2
PSUs)
792.27 BTU/hr
833.62 BTU/hr
743.82 BTU/hr
786.12 BTU/hr
12
Maximum
Power
Consumption
232.20 W
244.32 W
218.00 W
230.40 W