Provide enough space in front of and behind the switch so that you can service it easily. Allow a
minimum of 48 inches (122 cm) in front of the rack and 30 inches (76 cm) behind the rack.
Some ExtremeSwitching switches give you the option of choosing the airflow direction: front-to-back or
back-to-front. If your switch has internal power supplies, make sure they have the same airflow direction
as the fans in the switch.
Other switches support airflow in only one direction. If your switch model supports only front-to-back
airflow and requires the purchase of internal power supplies, make sure that the power supplies are for
front-to-back ventilation airflow.
The following items are provided with ExtremeSwitching switches:
Screws for attaching mounting brackets to the switch housing.
Two rack mounting brackets adaptable for either a front-mount or mid-mount installation.
Two rear mounting brackets (rails) for rear mounting in a four-post or cabinet installation.
Note
Rails are supplied only with the following switches:
X450-G2
X460-G2 PoE models:
X670-G2
X690
X770
X870
You need the following additional tools and equipment. These are not provided with your switch.
Rack mounting screws: eight for a four-post installation; four for other installations. The screw size
will vary based on your organization's rack system. Screws are not provided.
Screwdriver for securing the switch to the rack. The screwdriver size will vary based on the
requirements for the rack system you are using.
#2 Phillips screwdriver to attach bracket screws that are provided with the switch. We recommend
using a magnetic screwdriver.
AC power cord. For switches with removable AC power supplies, a separate power cord is needed
for each installed power supply. The cord must meet the requirements listed in
Requirements for AC-Powered Switches and AC Power Supplies
ESD-preventive wrist strap for installing optional ports at the back of the switch.

Attaching the Switch to a Rack or Cabinet

To attach a switch to a two-post rack, a four-post rack, or a cabinet, follow these steps.
ExtremeSwitching and Summit Switches: Hardware Installation Guide
X460-G2-24p-GE4
X460-G2-24p-10GE4
X460-G2-24p-24hp-10GE4
X460-G2-16mp-32p-10GE4
X460-G2-48p-GE4
X460-G2-48p-10GE4
Installing Your Extreme Networks Switch
Power Cord
on page 393.
181

Advertisement

Table of Contents
loading

Table of Contents