Switch Technical Specifications
Table 84: BlackDiamond 6800 model-specific unique specifications (Continued)
Temperature power-off

EPS-LD Power Supply Specifications

Table 85 lists the electrical specifications for each EPS-LD unit.
Table 85: EPS-LD power supply specifications
Ratings
Nominal Operating Voltage
Input Voltage Range
AC Line Frequency
Maximum Input Current Rating 10A at 115 VAC, 5A at 230 VAC
Maximum Inrush Current
Output
EPS-LD Input Connector
Maximum continuous DC output shall not exceed 465 Watts.
Acoustic Sound
Sound Power in accordance with
EN 300 753 (10-1997)
Sound Pressure in accordance
with NEBS GR-63, Issue 2
Table 86 lists the environmental specifications for each EPS-LD unit.
Table 86: EPS-LD operational environmental specification overview
Ratings
Ambient Operating Temperature
Storage and Transportation Temperature
Operating Relative Humidity
Shock—Operational
336
Original supply, not DC and not high-output: 75° C (167° F)
DC Supply:
Stand-alone: 65° to 70° C (149° to 158° F)
In chassis: 70° C (158° F)
High-output: 75° C (167° F)
115 VAC or 230 VAC
100 VAC to 240 VAC
50 Hz to 60 Hz
30A at 115 VAC, 60A at 230 VAC
-50 VDC, 7.5 A max, 375 Watts
12 VDC, 7.5 A max, 90 Watts
IEC320-C14
Sound Power: 62 dBA per ISO 7779
Declared Sound Power: 6.5 belsA per ISO 779 and ISO 9296
Bystander Sound Pressure: 54 dBA rear @ 0.6m
0 C to +40 C
-40 C to +70 C
10 - 95% noncondensing
30 m/s2 (3g)