10.5

Electrical installation

10.5.1

General information on how to install the drive controller

WARNING
Before working on live parts: De-energize installation and secure power
switch against unintentional or unauthorized re-energization.
Wait at least 30 minutes after switching off the supply voltages to allow
discharging.
Check whether voltage has fallen below 50 V before touching live parts!
Damage can be caused to the drive controller or circuit boards if electrostatic
charging present in people and/or tools is discharged across them. For this
reason, please observe the following information:
NOTICE
Exposed conductive parts coming into contact with components and circuit
boards must be discharged by means of grounding. Otherwise errors may
occur when controlling motors and moving elements.
Such exposed conductive parts include:
The copper bit when soldering
The human body (ground connection by touching a conductive,
grounded object)
Parts and tools (place them on a conductive support)
Endangered components may only be stored or dispatched in conductive
packaging.
Rexroth connection diagrams are only to be used for producing
installation
circuit
installation circuit diagrams must be used for wiring the
installation!
Lay signal lines separately from the load resistance lines because of the
occurrence of interference.
Transmit analog signals (e.g. command values, actual values) via
shielded lines.
Do not connect mains, DC bus or power cores to low voltages or allow
them to come into contact with these.
When carrying out a high voltage test or an applied-overvoltage
withstand test on the machine's electrical equipment, disconnect all
connections to the devices. This protects the electronic components
(allowed in accordance with EN 60204-1). During their routine testing,
Rexroth drive components are tested for high voltage (in accordance
with EN 61800-5-1:2007, section 5.2.3.2) and insulation (in accordance
with EN 60204-1:2006, section 18.3).
Mounting, dismounting and electrical installation
Lethal electric shock by live parts with more
than 50 V!
Electrostatic charges can cause damage to
electronic components and interfere with their
operational safety!
diagrams!