Xd10, 24 V Supply (Control Voltage) - Bosch Rexroth IndraDrive X Operating Instructions Manual

Table of Contents

Advertisement

84/123
Mounting, dismounting and electrical installation

XD10, 24 V supply (control voltage)

Function, pin assignment
View
Screw connection at connector
Connection cable
Stranded wire
Stripped length
Power consumption
Voltage load capacity
Current carrying capacity "looping through" from
0V to 0V, 24V to 24V
Polarity reversal protection
Insulation monitoring
Notes on installation
Bosch Rexroth AG R911392532_Edition 01
IndraDrive X Drive Controllers Power Sections XCS1, XMD1,
Via the connection point, the 24 V supply is applied externally for
the control section and power section of the drive controller
the brake control
the digital inputs and the digital output
Connectio
n
1
2
Unit
mm
2
AWG
mm
W
V
A
Within the allowed voltage range by internal protective diode
Tab. 10-16:
Function, pin assignment, properties
Requirements on the connection to the 24 V supply:
Minimum cross-section: 1 mm
Maximum allowed inductance: 100 µH (2 twisted single strands, 75 m
long)
Parallel line routing where possible
Depending on the power consumption of the devices and the current carrying
capacity of the connector, check the number of devices through which one
line for 24 V supply can be looped through. You might possibly have to
connect another device directly to the 24 V supply and then loop through the
control voltage from this device to other devices.
Signal name
0V
Reference potential for
+24V
min.
0.2
24
10
P
(see control voltage data)
N3
U
(see control voltage data)
N3
41
Possible
2
XMQ1
Function
power supply
Power supply
max.
6
8