Bosch Rexroth IndraDrive X Operating Instructions Manual page 117

Table of Contents

Advertisement

IndraDrive X Drive Controllers Power Sections XCS1, XMD1,
XMQ1
Color / flashing pattern
Flashing red
Flashing blue
Flashing red
Flashing yellow-
blue
Blue
Flashing blue
Off
LED
1)
1)
Flashing pattern: One square corresponds to a duration of
250 ms; the arrow marks the end of a cycle; abbreviations on
the squares: WH = LED permanently lit white, YE = LED per‐
manently lit yellow, BU = LED permanently lit blue, GN = LED
permanently lit green, RD = LED permanently lit red, -- = LED
is off
Tab. 12-5:
LED display for the states of the sub-device state machine and the
resource state machine
Significance
Measures
Communication error (F4xxx)
If necessary, read detailed state via "S‑0‑0095,
Diagnostic message"
All warnings
Command error
All errors (except F4xxx / F9xxx / E0800)
Read detailed state via "S‑0‑0095, Diagnostic
message" and carry out service function
Repair required
AF (drive in control)
Lb (supply unit in rectifier mode)
LB (supply unit in voltage control)
I LB (supply unit in current control)
AH (Drive Halt)
Ab (drive ready for operation, power on)
Bb (control section and power section ready
for operation, mains voltage available)
charg (DC bus charging active)
Supply unit not switched on
Check 24 V supply and switch it on, if not yet done
Cable interrupted
Check cable and connector
Hardware defective
Replace hardware
R911392532_Edition 01 Bosch Rexroth AG
101/123
Description of the devices
Priority
Low

Advertisement