Loading capacity
The loading capacity of the DC bus connection depends on the DC bus
power:
Components ≤ ...-W0120:
P
= 45 kW × [1 – (400 - U
DC_Bus_max (ULN)
P
= 45 kW × [1 + (U
DC_Bus_max (ULN)
Components > ...-W0120:
P
= 120 kW × [1 – (400 - U
DC_Bus_max (ULN)
P
= 120 kW × [1 + (U
DC_Bus_max (ULN)
The sum of P
of all components at the common DC bus should not
DC_Bus
exceed P
.
DC_Bus_max (ULN)