MMS200 Protocol
(version 1.1 JM 01/21/15)
Reference the sections below for DMX channel assignments. (Click Section Title to expand or collapse the section)
Motion Protocol
Motion Protocol
DMX Channel Name
1 + 2
Pan Coarse
Pan Fine
3 + 4
Tilt Coarse
Tilt Fine
5
mSpeed
6
control trigger
7
control
Note 1 - Control Hold
Note 6
Control Hold
The number in parenthesis indicates the number of consecutive times the value must be received from the DMX con-
Number (x)
troller before the indicated function is actuated. The dimmer, slot 5, is required to be closed during this time, DMX =
0.
Note
16 bit Channel
16 bit Channel
Hold 5 - Note 1
Hold 5 - Note 1
Hold 5 - Note 1
Hold 20 - Note 1
MMS200 User Guide --- (Details subject to change, and clarification)
Default Range
Action
32768
0 thru 65535 Pan Movement
32768
0 thru 65535 Tilt Movement
0
0 thru 255
mSpeed Control Values
127
0
0 - Triggers Control Channels
1-127
Fine Correction OFF
128-255
Fine Correction ON (future implementation)
0
0 thru 9
Safe
10 thru 19
Pan and Tilt mSpeed off
20 thru 28
Display Off
30 thru 38
Display On
40 thru 48
Home All
49 thru 70
(reserved)
71 thru 80
Shutdown fixture
81 thru 255
(reserved)