ELECTRICAL CONNECTION (190BM2E)
Important
The connection must be made by author-
ised, skilled personnel, in accordance with
the relevant legal requirements, using ap-
propriate and specified materials. The ap-
pliance is supplied with operating voltage
4000V/3N, which can be switched to 230V/3.
Caution - warning
Before doing any work, cut off the mains elec-
tricity supply.
Connect the appliance to the mains electricity sup-
ply as follows.
1 - If not already present, install a circuit-breaker
(A) with overload cutout and differential safety
breaker close to the appliance.
2 - Pull off the knob (B).
3 - Undo the screws (C) and remove the con-
trol panel (D).
4 - Connect the circuit-breaker (A) to the terminal
board (E) of the appliance as shown in the dia-
gram and in the electrical system diagram at
IT
CONVERSION OF ELECTRICITY SUPPLY (190BM2E)
GB
Important
The appliance is supplied at an operating
voltage 400V/3N (indicated on the sticker
DE
applied to the dataplate); conversion to
230V/3 can be carried out as described be-
FR
low.
ES
Caution - warning
Before doing any work, cut off the mains elec-
tricity supply.
1 - Pull off the knob (A).
2 - Undo the screws (B) and remove the control
panel (C).
3 - Modify the connections to the heating element
terminals (D) as shown in the electrical system
diagram at the back of the manual.
4 - Disconnect the wires 15-16 from the neutral
English
A
B
C
D
the back of the manual. Use a flexible cable
with at least type H07RN-F characteristics, rat-
ed for an operating temperature of at least
80°C.
Important
When connecting, take care to connect the
neutral and earth lines.
5 - Replace the control panel (D) on completion of
the operation.
A
B
C
and fit the jumper (E) across L3 and the neutral
as shown in the diagram and in the electrical
system diagram at the back of the manual.
5 - Replace the control panel (C) on completion of
the operation.
- 14 -
E
IDM-39615701400.tif
E
D
IDM-39615701500.tif